Change Of Set Flow And Hysteresis [Simple Setting Mode] - SMC Networks PF3A703H-L Operation Manual

Digital flow switch
Hide thumbs Also See for PF3A703H-L:
Table of Contents

Advertisement

Change of Set Flow and Hysteresis [Simple setting mode]

■Simple setting mode
In the simple setting mode, the set value, hysteresis and delay time can be changed while checking the
current flow value (main display).
<Operation>
[Hysteresis mode]
(1) Press the S button for 1 second or longer (but less than 3 seconds) in measurement mode. [SEt] is
displayed on the main display.
When the button is released while in the [SEt] display, the current flow value is displayed on the main
display, [P_1] or [n_1] is displayed on the sub display (left) and the set value is displayed on the sub
display (right).
(2) Change the set value using the ▲ or ▼ button, and press the SET button to set the value. Then, the
setting moves to hysteresis setting.
(The snap shot function can be used. (Refer to page 66))
(3) Change the set value with the ▲ or ▼ button, and press the S button to set the value. Then, the setting
moves to the setting of OUT2.
(The snap shot function can be used. (Refer to page 66))
(4) Like the setting of OUT1, the setting returns to the setting of OUT2 by pressing the S button after
setting the set value and hysteresis.
(5) Press and hold the S button for 2 seconds or longer to complete the simple setting.
(If the button is pressed for less than 2 seconds, the setting will be returned to P_1.)
1: Selected items of (1) to (4) become valid after pressing the S button.
2: After enabling the setting by pressing the S button, it is possible to return to measurement mode by pressing the S button
for 2 seconds or longer.
3: When the output mode is set to accumulated pulse, error output or output OFF (refer to page 37), the simple setting mode
cannot be used.
(the setting returns to measurement mode by releasing the button when [SEt] is displayed.)
: When [F 1] and [F 2] are set to accumulated pulse
output, error output or output OFF [---] will be
displayed in the sub screen when [SEt] is displayed.
It is not possible to move to the Simple setting mode.