Analogue output check
Press the ▲ or ▼ button to select
analogue output check.
: When 0-10V is selected for voltage output type, [ 0.0]  [ 10.0] is displayed.
: For current output type, [ 4]  [ 20] is displayed.
When the product is used
in SIO mode
Press the S button to set.
Move on to function
selection mode.
PD diagnostic bit (flow) check
Press the ▲ or ▼ button to select
diagnostic bit (flow) check.
: This function is available with IO-Link communication.
: Refer to page
Press the SET button to set.
-63-
Accumulated pulse output check
Accumulated pulse is output for
10 times by pressing the ▲ button.
Accumulated pulse is stopped by
pressing the ▼ button.
: When the converted pulse value is 100 L/pulse, the value is
changed from 0 to 1000 by pressing the ▲ button once (total
of 10 times of output). If the ▲ button is pressed again, the
value is changed from 1000 to 2000.
77
for details of the diagnostic information.
Move on to analogue
output check.
When the product is used
in SDCI mode (IO-Link)
Press the S button to set.
Move on to the PD
diagnostic bit check.
Move on to PD diagnostic bit
(flow) check.
No.PF※※-OMX0002