<Operation>
[Hysteresis mode]
In the 3 step setting mode, the set value (P_1 or n_1) and hysteresis (H_1) can be changed.
Set the items on the sub display (set value and hysteresis) using the ▲ or ▼ buttons.
When changing the set value, follow the operation below. The hysteresis setting can be changed in the
same way.
(1) Press the S button once when the item to be changed is displayed on the sub display.
The set value on the sub display (right) will start flashing.
(2) Press the ▲ or ▼ button to change the set value.
The ▲ button is to increase and the ▼ button is to decrease the set value.
●Press the ▲ button once to increase the value by one digit, press and hold to continuously increase.
●Press the ▼ button once to reduce the value by one digit, press and hold to continuously reduce.
●When ▲ and ▼ buttons are pressed simultaneously for 1 second or more, the set value is displayed
as [ - - - ], and the set value will be set to the same as the displayed value automatically (snap shot
function) (Refer to page 66). Afterwards, it is possible to adjust the value by pressing ▲ or ▼ button.
(3) Press the S button to complete the setting.
-27-