Outline of Settings [Measurement mode]

The output will not operate for 3 seconds after supplying power.
Measurement mode is the condition where the flow is detected and displayed, and the
switch function is operating.
This is the basic mode; other modes should be selected for set-point changes and other
function settings.
Measurement mode screen
Sub display
In measurement mode, the display of the sub display can be temporarily changed by pressing the
▲ or ▼ buttons.
: Arbitrary display mode can be added to the sub display by setting the [F10] sub display.
(The default setting does not include arbitrary display.)
: The example shown is for the 3000 L/min type.
: OUT2 set value/hysteresis settings are not available.
(OUT2 switch output does not exist in the output specification of this model)
Press S button
once.
Change of Set
Value
(3 step setting mode)
(Refer to page 26)
: The outputs will continue to operate during setting.
 If a button operation is not performed for 3 seconds during the setting, the display will flash. (This is to prevent the setting from
remaining incomplete if, for instance, an operator were to leave during setting.)
 3 step setting mode, simple setting mode and function selection mode settings will reflect on each other.
Power is supplied.
The identification code of the product is displayed.
[Measurement mode]
Press the
S button for
1 to 3 seconds.
Change of Set
Flow and
Hysteresis
(Simple setting mode)
(Refer to page 29)
Press the
S button for
3 to 5 seconds.
Change the
Function
Settings
(Function selection
mode)
(Refer to page 31)
-25-
Other Settings
(Refer to page 66)
No.PF※※-OMX0002