Fitting

9.3.5 Fitting the magnetic foot

Tools:
-
Assembly aid
- M5x30 screw
- M5 nut
-
Socket head wrench, 5 mm
-
Torx T10
1
2
C-SC_CSSM
3
Version 1.0
All rights reserved by FEIN, especially in case of property rights applications.
FEIN retains all rights of disposal, such as copying and circulation.
1.
Place the magnet on a steel plate.
2.
Screw in the screw (1).
I
NFORMATION
Screw in the screw by max. 5 mm as, otherwise, the lever (3)
cannot be fitted.
3.
Tighten the lock nut (2).
4.
Turn the screw anticlockwise.
I
NFORMATION
Turn to the "30%" position.
5.
Position the lever (3).