4.5. Changing a Power Supply Back To a Standalone
Unit
To release a unit from parallel operation and change it back to a
Standalone unit, do the following:
1. Turn the Power Switch on all parallel units to the OFF position.
2. Disconnect the connections to the positive terminal (labeled
"POS"), negative terminal (labeled "NEG"), and SHARE interface
(labeled "A" and "B").
3. Turn the unit's Power Switch to the ON position.
4. In the front Control Panel menu, go to the Parallel Settings
screen.
5. Scroll to the Parallel Mode setting and press Enter. Scroll and
choose Standalone as the parallel mode setting, then press
Enter.
6. The unit is now configured as a Standalone unit. If the unit was
previously configured as a Secondary unit, the System Settings
Control Panel screen will now be unlocked. Note that when the
Parallel Mode setting (Standalone/Primary/Secondary) is
changed to a different setting on a unit, the DC Output of that
power supply will automatically be turned OFF if it is currently
enabled. You will need to verify the output voltage/current
settings, and then manually enable the output.