Rear Panel (N5173B/83B); Tools Required; Removal Procedure; Replacement Procedure - Keysight Technologies X Series Service Manual

Signal generators
Hide thumbs Also See for X Series:
Table of Contents

Advertisement

Assembly Replacement

Rear Panel (N5173B/83B)

Rear Panel (N5173B/83B)

Tools Required

— T-10 driver
— 5/8" hex-nut driver (p/n: 8710-2546)

Removal Procedure

Refer to
1. Disconnect the power cord.
2. Remove the covers from the signal generator. Refer to
3. Place the signal generator flat with the rear panel facing you.
4. If Option 006 is installed, refer to
5. Using the 5/8" hex-nut driver, remove the nuts and washers (1) securing
6. Using the T-10 driver, remove the two screws (2) (0515-1227) and the
7. Pull the rear panel away from the signal generator's chassis.

Replacement Procedure

1. Reverse the order of the removal procedure.
2. Recommended torque for all screws is 9 in–lbs.
3. Recommended torque for all BNC connectors is 21 in–lbs.
408
Figure 15-41
for this procedure.
page
336,
"Inner Top Cover" on page
page
340.
card (1) and cover (2).
the A3 RF assembly BNC's to the rear panel.
eleven screws (3) (0515-0372) securing the rear panel to the signal
generators chassis.
Keysight CXG, EXG, and MXG X-Series Signal Generators Service Guide
"Outer Cover" on
338, and
"Inner Bottom Cover" on
Figure
15-42. Remove the Flash Memory

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents