Connecting The Cabinet Units - Siemens SINAMICS S120 Manual

Cabinet modules liquid-cooled
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Note
Attach the sealing tape beforehand
Before assembly, the supplied sealing tape from the accessories kit must be attached.
Installing the pipe couplings
1. Locate the pipe couplings so that they are centered over the connection points of the
collecting pipes.
2. Tighten the socket-heat screws with the torque specified for the pipe couplings.
3.3.5.2

Connecting the cabinet units

Description
An accessories kit is provided with each cabinet or transport unit for the connection of
cabinet units in a side-by-side installation. The table below shows the content of this
accessories kit for connecting the cabinet units.
Table 3- 3
Content of the accessories kit for connecting the cabinet units
Quantity
Material
1 x
Sealing strip
3 x
Outer cabinet connectors
including Mounting material
3 x
Inner cabinet connectors
including Mounting material
Cabinet Modules liquid cooled
Manual, 10/2015, A5E37067587A
Figure
Notes
The sealing strip must be glued to the cabinets before
connecting them.
The cabinet connector is fitted and screwed on from
the outside.
Tightening torque: 9 Nm
The cabinet connector is fastened with 4 screws.
Tightening torque: 5 Nm
Mechanical installation
3.3 Installing
59

Advertisement

Table of Contents
loading