Siemens SINAMICS S120 Manual page 281

Cabinet modules liquid-cooled
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

LED
Color
Green/orange
or
Red/Orange
L1+, L2+,
Red
L3+
Red
Fail-safe inputs / double inputs
F_DI z
LED
LED
(input x,
x
x+1
(x+1)+,
Red
(x+1)-)
Red
LED
LED
x
x+1
Green
Green
Green
Green
Single digital inputs, not fail-safe
DI x
Green
Fail-safe digital outputs with associated readback channel
F_DO y
Green
(0+..3+,
0-..3-)
Read back input DI 2y for output F_DO y (y = 0 ... 3) for test stop. The state of the LEDs depends on the type of external
circuitry.
DI 2y
Green
Inputs x+1 (DI 1+, 3+, .. 19+) can be individually adjusted by a parameter (see SINAMICS S120/S150 List Manual)
1)
Cabinet Modules liquid cooled
Manual, 10/2015, A5E37067587A
State
Flashing light
Detection of the components via LED is activated (p0154).
Note:
Both options depend on the LED status when module recognition is
activated via p0154 = 1.
On
The controllable sensor power supply is functioning fault-free.
Steady light
There is a fault in the controllable sensor power supply.
On
The sensor power supply is operating fault-free.
Steady light
The sensor power supply has a fault.
NC contact/NC contact
Steady light
Different signal states at input x and x+1
No signal at input x and no signal at input x+1
NC contact/NO contact
Steady light
Same signal states at input x and x+1
No signal at input x and no signal at input x+1
NC contact/NC contact
Steady light
One signal at input x and one signal at input x+1
NC contact/NO contact
Steady light
One signal at input x and no signal at input x+1
Off
No signal at digital input x (x = 20 ... 23)
Steady light
Signal at digital input x
Steady light
Output y (y = 0 ... 3) has an active signal
Off
One of the two output lines y+ or y- or both lines of output y carry a
signal
Steady light
Both output lines y+ and y- carry no signal
8.13 LEDs on the TM54F Terminal Module
Description, cause
: (z = 0 ... 9, x = 0, 2, ... 18)
1)
: (z = 0 ... 9, x = 0, 2, ... 18)
1)
: (z = 0 ... 9, x = 0, 2, ... 18)
1)
: (z = 0 ... 9, x = 0, 2, ... 18)
1)
Diagnostics
281