Installation steps
Installing is the same as removing, however in the reverse order.
Tightening torque for the fastening screws of the Control Interface Module (M6 x 16, item
④
): 6 Nm
Note
Specifications for the installation
The tightening torques specified in the table "Tightening torques for screw connections" must
be observed.
Carefully insert the plug connections and ensure that they are secure.
When using connectors with a locking mechanism, make sure that the locking lever is
securely engaged once connected.
The DRIVE-CLiQ cable connectors should be labeled prior to disassembly and reinstalled at
their original slot, since it is necessary to re-perform system identification after changing the
DRIVE-CLiQ cables.
The screw connections for the protective covers may only be tightened by hand.
7.5.8
Replacing the fuses
7.5.8.1
General information
Replacement fuses
Article numbers for replacing fuses that have blown are contained in the spare parts list.
7.5.8.2
Replacing the fuses for the auxiliary power supply
Replacement fuses
You can find the article numbers in the spare parts list for replacing auxiliary power supply
fuses that have blown.
Note
The fuses for the auxiliary power supply are freely accessible and can be replaced once the
fault cause has been eliminated.
Cabinet Modules liquid cooled
Manual, 10/2015, A5E37067587A
Maintenance and servicing
7.5 Replacing components
253