Article No.
Volume of liquid
- degree of protection <IP55
- degree of protection IP55
Cooling air requirement
Sound pressure level L
pA
Line connection L1, L2, L3
- connection cross-section, max (IEC)
PE/GND connection
- Busbar cross-section
- Connection cross-section, max. (IEC)
Cable length, max.
4)
- Shielded
- Unshielded
Degree of protection (standard version)
Dimensions (standard version)
- width
- height
- depth
Weight (standard version)
Frame size
- Line Connection Module
- Basic Line Module
Rated short-circuit current acc. to IEC
Minimum short-circuit current
The base load current I
1)
The specified power loss represents the maximum value at 100 % capacity utilization. The value in normal operation is
2)
lower.
This value applies to the water coolant option; for other coolant types, see Chapter "Coolant".
3)
Total of all motor cables and DC link. Longer cable lengths for specific configurations are available on request.
4)
Minimum current required for reliable tripping of the protective devices.
5)
Cabinet Modules liquid cooled
Manual, 10/2015, A5E37067587A
(1 m) at 50/60 Hz
5)
is based on a duty cycle of 150% for 60 s or I
H DC
6SL3735-
1TE37-4LA3 1TE41-2LA3 1TE41-7LA3
dm³
6.6
dm³
10.2
m
/s
0.272
3
dB(A)
54
2/M12
mm
4 x 240
2
mm
2
mm
2
m
2600
m
3900
IP21
mm
1000
mm
2200
mm
600
kg
688
HL
FBL
kA
65
A
8800
max DC
Cabinet Modules
6.1 Basic Line Connection Modules
6.6
6.9
10.2
10.5
0.272
0.272
56
56
5/M12 +
5/M12 +
4/M16
4/M16
8 x 240
8 x 240
PE busbar
600
240
4000
4800
6000
7200
IP21
IP21
1000
1000
2200
2200
600
600
838
995
JL
JL
FBL
GBL
84
100
2000
3200
for 5 s with a duty cycle duration of 300 s.