Siemens SINAMICS S120 Manual page 300

Cabinet modules liquid-cooled
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Options
9.6 G60, Terminal Module TM31
X500, X501: DRIVE-CLiQ interface
Table 9- 6
DRIVE-CLiQ interface X500 and X501
1
2
3
4
5
6
7
8
A
B
Blanking plate for DRIVE-CLiQ interfaces (50 pcs.) Article number: 6SL3066-4CA00-0AA0
X520: 4 digital inputs
Table 9- 7
DI: digital input; M1: ground reference; M: Electronics ground
1)
Max. connectable cross-section: 1.5 mm²
300
Pin
TXP
TXN
RXP
Reserved, do not use
Reserved, do not use
RXN
Reserved, do not use
Reserved, do not use
+ (24 V)
M (0 V)
Terminal block X520
Terminal
Designation
1
2
3
4
5
6
Signal name
1)
DI 0
Voltage: - 3 ... +30 V
Current consumption Typical: 10 mA at 24 V DC
DI 1
Input delay:
DI 2
for "0" to "1": Typ. 50 µs max. 100 µs
DI 3
for "1" to "0": Typ. 130 µs, max. 150 µs
M1
Electrical isolation:
Reference potential is terminal M1
M
Signal level (including ripple)
High level: 15 ... 30 V
Low signal level: -3 ... +5 V
Technical data
Transmit data +
Transmit data -
Receive data +
Receive data -
Power supply
Electronics ground
Technical data
Cabinet Modules liquid cooled