9.11 K46, Sensor Module Cabinet-Mounted SMC10
Table 9- 18
Transmission ratio of the resolver
Excitation voltage on the SMC10 for ü = 0.5 (cannot be parameterized)
Amplitude monitoring threshold (secondary tracks) of the SMC10
The maximum encoder cable length is 130 m.
The excitation frequency is synchronized to the current-controller clock cycle and lies in the
range between 5 kHz and 10 kHz.
The ratio between ohmic resistance R and inductance L determines whether the resolver
can be evaluated with the SMC10 (see diagram below).
Figure 9-17
318
SMC10 specification
Connectable impedances with an excitation frequency f = 5000 Hz
Value
ü = 0.5
4.1 V
rms
1 V
rms