Siemens SINAMICS S120 Manual page 112

Cabinet modules liquid-cooled
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Electrical installation
4.5 Connections
1. Route the encoder connecting cable into the cabinet from the bottom.
2. Remove approx. 3 cm of the insulation at the level of the shield plate in the lower part of
the cabinet and attach the cable there.
3. To secure the cable in accordance with EMC requirements, snap the clip onto the shield
plate.
4. Use cable ties to secure the cable at suitable points.
5. Route the cable further up into the cabinet and, when it reaches the SMC10/20/30 Sensor
Module (-B81/-B82/-B83), guide it to the right to the Sensor Module. When doing so,
route the cable in a similar manner to the standard cables that have already been
installed in the cabinet.
6. Use cable ties to secure the cable at suitable points.
7. Connect the cable at the encoder module SMC10/20/30 (-B81/-B82/-B83).
(→ See Chapter "Options", K46, K48 and K50 (Sensor Module Cabinet-Mounted SMC 10,
20 and 30))
Cable routing for the Terminal Module TM54F
Note
Cable routing
The procedure is analogous to the signal cables to the encoder module.
Connect the cable to the terminals to control the functions.
(→ See Chapter "Options", Section "K87, Terminal Module TM54F")
Cable routing for Safe Brake Adapters SBA 230 V AC
Note
Cable routing
The procedure is analogous to the signal cables to the encoder module.
Connect the cable to the terminals to control the functions.
(→ See chapter "Options" in Section "K88, Safe Brake Adapter SBA AC 230 V"")
112
Cabinet Modules liquid cooled
Manual, 10/2015, A5E37067587A