Mechanical installation
3.3 Installing
Figure 3-13
Connecting the collecting pipes
The collecting pipes are connected in the sequence:
1. Install the cabinet units at the intended location.
2. Remove the protective caps from the collecting pipes.
3. Ensure that the support rings are inserted in the connection locations of the collection
pipe. Ensure that the support rings are flush with the collection pipe.
4. Insert the pipe couplings into the collecting pipes of the left-hand or right-hand cabinet
unit.
5. Move the cabinet units together to the final installation dimension, also see Connecting
the cabinet units (Page 59).
6. Align the individual cabinet units so that they are in a perfectly straight line and at the
same height. This may require the use of leveling measures, such as the insertion of
spacer plates. Ensure that the water pipes precisely line up axially with one another.
58
Collecting pipes with inserted support rings
Cabinet Modules liquid cooled
Manual, 10/2015, A5E37067587A