Siemens SINAMICS S120 Manual page 333

Cabinet modules liquid-cooled
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

X520 encoder connection 1 for HTL/TTL/SSI encoder with open-circuit monitoring
Table 9- 24
Encoder connection X520
Pin
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
Connector type: 15-pin Sub-D socket
NOTICE
Damage to the motor in the event of incorrectly connected KTY temperature sensor
A KTY temperature sensor connected with incorrect polarity cannot detect if the motor
overheats. Overheating can cause damage to the motor.
• Connect a KTY temperature sensor with the correct polarity.
NOTICE
Damage to the encoder due to incorrect supply voltage
The encoder power supply can be parameterized to 5 V or 24 V. The encoder may be
damaged if you enter the wrong parameter.
• Select the appropriate supply voltage.
Cabinet Modules liquid cooled
Manual, 10/2015, A5E37067587A
Signal name
+ Temp
Clock
Clock*
P encoder 5 V / 24 V
P encoder 5 V / 24 V
P sense
M encoder (M)
- Temp
M sense
R
R*
B*
B
A*/data*
A/data
9.13 K50, Sensor Module Cabinet-Mounted SMC30
Technical data
Motor temperature sensing KTY84-1C130 (KTY+)
Temperature sensor KTY84-1C130/PTC/
bimetallic switch with NC contact
SSI clock
Inverted SSI clock
Encoder power supply
Encoder power supply
Sense input for encoder power supply
Ground for encoder power supply
Motor temperature sensing KTY84-1C130 (KTY-) Tem-
perature sensor KTY84-1C130/PTC/
bimetallic switch with NC contact
Ground for sense input
Reference signal R
Inverted reference signal R
Inverted incremental signal B
Incremental signal B
Inverted incremental signal A/inverted SSI data
Incremental signal A/SSI data
Options
333