9.20 K94, Performance extension for CU320-2

9.20
K94, Performance extension for CU320-2
Availability of option
This option is available for the following options:
● Option K90, Control Unit CU320-2 PROFIBUS
● Option K95, Control Unit CU320-2 PROFINET
Description
A CU320-2 Control Unit can perform the communication, open-loop and closed-loop control
functions for several power units. The computing capacity requirement increases in
proportion to the number of power units and system components and in relation to the
dynamic response required. The full computing capacity of the CU320-2 Control Unit is
available only with performance enhancement.
In addition to the firmware, the memory card also contains licensing codes, which are
required to enable firmware options (such as performance enhancement and the Safety
Integrated Extended functions).