6.1.2 Removing and attaching the unit cover

NOTICE
1. Place the top of the back wall in position first and then press against
the seal at the bottom.
2. Slide the back wall up.
3. Install screws in the back wall.
The back wall must be in contact with the unit on all sides.
Removing the unit cover on a tabletop unit
b
a
Image: Removing the unit cover
a Unit cover
b Steam outlet nozzle
c Seal
1. Unscrew the lid from the air inlet nozzle.
2. Remove the ventilator ring.
3. Unscrew the screws on the unit cover.
4. Carefully remove the unit cover.
Attaching the unit cover on a tabletop unit
Risk of property damage from leaky housing
• Check seals when attaching the housing parts.
• Replace damaged seals.
1. Brush the seal on the steam outlet nozzle with an acid-free slip
agent.
2. Carefully push the unit cover over the steam outlet nozzle and air
inlet nozzle.
The air inlet nizzle must be pushed through the cut-outs on the
unit cover.
3. Press the unit cover onto the housing.
4. Screw in the screws on the unit cover.
The unit cover must be in contact with the unit on all sides.
Installation instructions
c
d
e
f
d Lid
e Ventilation ring
f Air inlet nozzle
Connecting the unit
25