Attaching and Removing the Unit

4.2 Attaching the Unit

Requirements All required parts are available.

4.3 Removing the Unit

Requirements Combisteamer switched off and cooled down
12
Minimum Clearances
The following minimum clearances from walls, ceilings or other
equipment must be provided when installing the unit.
At least 500 mm in all directions.
a Smoker box
b Seal
1. Place the smoker box (a) on the combisteamer.
2. Open the cover and place seal (b) on the intake pipe of the
combisteamer.
3. Connect smoker box and combisteamer intake pipe by means of
the connecting pipe (c).
4. Remove the cover of the smoker box port from the combisteamer.
5. Insert the connector plug for the connection line.
6. Insert the firebox into the smoker box.
The smoker box is now ready for use.
Smoker box switched off and cooled down
1. Remove the cooled firebox.
2. Remove the connection line from the combisteamer port (d).
3. Place the cover on the port at the combisteamer and engage it.
4. Remove connecting pipe (c) between smoker box and
combisteamer intake pipe.
5. Remove smoker box (a) from combisteamer.
Installation Instructions
c
b
c Connecting pipe
d Connection line
a
d