7 Installing The Unit - Henny Penny FlexFusion ELECTRIC SPACESAVER PLUS FSE-610 Installation Manual

Hide thumbs Also See for FlexFusion ELECTRIC SPACESAVER PLUS FSE-610:
Table of Contents

Advertisement

Installing the unit
7 Installing the unit
CAUTION
CAUTION
CAUTION
Prerequisite Electrical connection made
38
Danger due to heavy weight of the unit (over 60 kg (132 lb))
• Erect the unit with several people.
• Raise / lower the unit with suitable lifting equipment.
Risk of crushing from improper installation
• Protect the unit and work area during installation and alignment.
Risk of crushing fingers and hands when lifting and lowering the
unit on the shelf plate
• Always lift and lower the unit (with suitable lifting equipment) carefully with
two people.
Image: Placing the unit on the slide-in plate
Water connection made or prepared
Waste water connection made or prepared
Housing closed
1. Place unit over the upper right bolts on the slide-in plate.
Bent edge of slide-in plate is at front.
2. Lift unit with slide-in plate and slide into place.
3. Complete remaining work for connecting the unit (see "Connecting
the unit").
4. Complete the start-up operation report.