Sync Type

[:SENSe]:SYNC ESECond|EXTernal[1]|EXTernal2|NONE|PSEQuence
[:SENSe]:SYNC?
Select the demodulation sync type for the waveform accuracy (Rho) and
code domain power measurements.
Even Second - Even second clock
External1 - front panel external trigger input
External2 - rear panel external trigger input
None - no demod sync (uses free run trigger)
Pilot Sequence - pilot sequence sync (uses frame trigger)
Factory Preset
and *RST:
Even second
Remarks:
Global to the current mode.
You must be in the cdmaOne mode to use this
command. Use INSTrument:SELect to set the mode.
Front Panel
Access:
Mode Setup, Trigger, Sync Type
History:
Front/Rear panel swapped EXT2/EXT1, A.03.00
Sync Alignment
[:SENSe]:SYNC:ALIGnment GSM|HBIT
[:SENSe]:SYNC:ALIGnment?
Select the sync alignment to be either to the GSM standard or the
standard offset by 1/2 bit.
GSM - burst alignment as defined in the GSM standard
HBIT - burst alignment is advanced by1/2 bit, which corresponds to
an earlier interpretation of the GSM standard
Factory Preset
and *RST:
Half bit
Remarks:
Global to the current mode.
You must be in the EDGE(w/GSM), GSM mode to use
this command. Use INSTrument:SELect to set the
mode.
Front Panel
Access:
Mode Setup, Demod, Burst Align