Radio Carrier Hopping - Agilent Technologies E4406A VSA Series Programmer's Manual

Transmitter tester
Hide thumbs Also See for E4406A VSA Series:
Table of Contents

Advertisement

Language Reference
SENSe Subsystem

Radio Carrier Hopping

[:SENSe]:RADio:CARRier:HOP OFF|ON|0|1
[:SENSe]:RADio:CARRier:HOP?
Turns the carrier hopping mode on and off.
Factory Preset
and *RST:
Off
Remarks:
Global to the current mode.
You must be in the EDGE(w/GSM), GSM mode to use
this command. Use INSTrument:SELect to set the
mode.
History:
Version A.03.00 or later
Front Panel
Access:
Mode Setup, Radio, Carrier
Radio Carrier Multiple
[:SENSe]:RADio:CARRier:NUMBer SINGle|MULTiple
[:SENSe]:RADio:CARRier:NUMBer?
Select if single or multiple carriers are present on the output of the base
station under test. This enables/disables a software filter for the rho
and code domain power measurements.
Factory Preset
and *RST:
Single
Remarks:
You must be in the , iDEN mode to use this command.
Use INSTrument:SELect to set the mode.
Front Panel
Access:
Mode Setup, Demod, RF Carrier
316