Ê Shut down the operating system.
Ê Switch off the server, and disconnect it from the main power supply.
V
CAUTION!
The power switch does not disconnect the device from the line
voltage. To disconnect the line voltage completely, remove the power
plug from the grounded power outlet.
Ê Open the server, and remove the front doors, the top cover, the side cover,
and the slot cover (see chapter "Opening and closing the server" on
page 47).
Ê Remove the front panel (see section "Removing/mounting the front panel"
on page 98).
Figure 57: Removing the floor stands
Ê Lay the server on its right side (as shown in figure 57). Remove the fastening
screws, and take off the floor stands (1).
Ê Remove the cage for the accessible drives (CD) (see section "Accessible
drives" on page 75).
Ê Carefully pull out 1/3 of the cage for the hard disk drives from the cage
guides (see section "Converting 1 to 2-channel version (1.6-inch HD
subsystem)" on page 101).