Fujitsu PRIMERGY H200 Manual page 118

Table of Contents

Advertisement

Upgrading second SCSI backplane (1-inch HD subsystems)
Cable designations
No.
Description
1, 2 DC Power
3
I2C bus
6, 7 SCSI long (100 cm)
Ê Reconnect the cables to the SCSI backplane if you disconnected them to
mount the second SCSI backplane.
Ê Thread the SCSI cable (7) through the opening in the separation wall of the
server, and route them to the system board.
Ê Carefully insert the cage for the hard disk drives, without tilting, into the cage
guides, and slowly guide the SCSI cable (7) along.
Ê Connect the two SCSI cables to the corresponding connectors (SCSI A and
SCSI B) on the system board or the disk array controller. Refer to the
documentation for the system board for assistance.
Ê Reach through the CD drive cage aperture, and ensure that no cables are
being pinched.
Ê Remount the cage for the accessible drives (CD) (see section "Accessible
drives" on page 75).
Ê In the marked order, reinsert the hard disk drive modules, remount all
housing components, and close the server as described in chapter "Opening
and closing the server" on page 47.
108