Black Box 16 port User Manual page 76

16 and 24 port console servers
Hide thumbs Also See for 16 port:
Table of Contents

Advertisement

Service option
Description
PPP
When you want a remote access service connection using PPP, or when you
want to use the unit as a router with PPP. In both cases the user (whether real or
dummy) will be authenticated within PPP (provided you use Security - PAP or
CHAP).
cslogin
When you want a remote access service connection using SLIP. Do not use the
option 'SLIP' because there would be no authentication of the user; (instead,
you will set SLIP for a particular user - see
100).
Choosing the 'cslogin' option, the unit will present the login prompt: the user
will be required to enter a name and password and hence will be authenticated.
SLIP
When you want to use the unit as a router with SLIP. There will be no
authentication of each unit by the other unit.
Option
Description
Line name can be configured to uniquely identify the line.
Line name
Speed, Bits,
Change as necessary from the default line configuration of 9600 baud, 8 data
Parity and
bits, no parity, 1 stop bit.
Stop
Flow
Flow Control field to either 'soft' (software) or 'hard' (hardware). For SLIP set to
'hard' only. For PPP set to either 'soft' or 'hard' ('hard' recommended). If you
select 'soft' you must set the parameter ACCM when you configure PPP for the
line (in Configuring PPP on page 82)
Host port field. This is the host TCP port number and is set by default to 23. In most cases you
can use the default value.
Dial
Set to 'in' if your user is remote and will be dialling in via modem or ISDN TA;
set to 'in' or 'out' if using the unit as a router, depending on which end of the
link your unit is situated.
Phone Number When dial is set to 'out' and the line 'service' is set to 'slip' or 'ppp' enter a
phone number for the unit to dial (you should only have this combination of
settings when you are using two units back-to-back, i.e. as routers.
Idle Timer
Enter a period in seconds for which the idle timer will run. Use this timer to
router use only
close a connection because of inactivity. When the idle timer expires the unit
will end the connection. The default value is 300 seconds, meaning the idle
timer will expire 300 seconds after the last activity. The maximum value is
4294967 seconds (equal to 49 days, approximately). A value of 0 (zero) means
the idle timer will not expire, so the connection is open permanently.
Black Box Console Server user guide
Configuring a user account on page
76