Order toll-free in the U.S.: Call 877-877-BBOX (outside U.S. call 724-746-5500) FREE technical support 24 hours a day, 7 days a week: Call 724-746-5500 or fax 724-746-0746 SUPPORT Mailing address: Black Box Corporation, 1000 Park Drive, Lawrence, PA 15055-1018 INFORMATION Web site: www.blackbox.com • E-mail: info@blackbox.com...
Page 3
FEDERAL COMMUNICATIONS COMMISSION CANADIAN DEPARTMENT OF COMMUNICATIONS RADIO FREQUENCY INTERFERENCE STATEMENTS This equipment generates, uses, and can radiate radio frequency energy and if not installed and used properly, that is, in strict accordance with the manufacturer’s instructions, may cause interference to radio communication. It has been tested and found to comply with the limits for a Class A computing device in accordance with the specifications in Subpart J of Part 15 of FCC rules, which are designed to provide reasonable protection against such interference when the equipment is operated in a commercial environment.
FOM LINE DRIVER—ST AND S M 1. Specifications Asynchronous Protocol — Transparent through 20 Kbps on 20-mA current loop port, Speed — 64 Kbps on RS-232 port, 128 Kbps on RS-485 port 5000 feet (1524 m) on 62.5 micron Maximum Distance — Network or master/slave mode, multipoint half-duplex (NOTE: A Operation —...
FOM LINE DRIVER—ST AND S M 2. Introduction With the FOM Line Driver, you can use an RS-232, RS-485, or 20-mA digital current-loop device in a multi-drop half-duplex or point-to-point full-duplex environment using fiber optics as the transmission media. The Driver is user-configurable in any of these operating modes: network mode, master/slave mode, or full-duplex point-to-point configuration.
FOM LINE DRIVER—ST AND S M 3. Configurations There are three operating modes you can choose from: network mode, master/slave mode, or point-to- point configuration. In network mode, all of the units are configured. If you want one Line Driver configured as a master and the others as slaves, you need to be in master/slave mode.
FOM LINE DRIVER—ST AND S M 3.2 Master/Slave Mode When the master sends data to the transmitter (TX) of the RS-232 DB9, the 20-mA current loop, or the RS-485 terminal block, the data is passed through to the master’s B optical port. From there, it is daisychained to each slave’s B optical RX.
FOM LINE DRIVER—ST AND S M 3.3 Point-to-Point Set up as shown in Figure 3-3, the Line Driver can run in full-duplex mode across the fiber connecting an RS-232, RS-485, or 20-mA current-loop device to another RS-232, RS-485, or 20-mA current-loop device. FIBER OPTIC CABLE TERMINAL...
FOM LINE DRIVER—ST AND S M 4. Installation 4.1 Setup Factory-default settings are marked with asterisks. Determine which interface should be active, and set XW2 accordingly. RS-232 ........XW2A* RS-485 ........XW2B 20-mA Current Loop ....XW2C Determine the mode in which you want the Line Driver to operate. If you want all of the Line Drivers to be configured, choose 0 (on S1, position 1) for Network Mode.
FOM LINE DRIVER—ST AND S M Fiberoptic Cable Connections Because of the subtleties of the various modes of operation, review , for the Chapter 3, Configurations proper inter-unit connections. If you chose XW2A (RS-232) as your interface selection, go to .
FOM LINE DRIVER—ST AND S M 4.3 RS-485 Follow these instructions to set up the RS-485 interface. Set the wire to TB1 (the 4-wire terminal block) as indicated Connect the wire to the terminal block. below for 4-wire RS-485 applications: Position 1 ------Receive B positive Position 2 ------Receive A negative Position 3 ------Transmit B positive...
Page 13
FOM LINE DRIVER—ST AND S M S1 positions 3 through 6, when in the 1 or Biased, Failsafe Operation (S1, positions 3 through 6). ON position, switch in a 1K pull-up resistor to the A input/output and a 1K pull-down to the B input/output (see Figure 4-1).
FOM LINE DRIVER—ST AND S M 4.4 20-mA Current Loop (Point to Point) NOTE To use the following switch positions appropriately, you should have a firm understanding of your network requirements. Set the wire to TB1 (the 4-wire terminal block) as indicated Connect the wire to the terminal block.
FOM LINE DRIVER—ST AND S M 5. Quick Setup Guide XW1B = Sets the RS-232 interface for DTE XW1A = Sets the RS-232 interface for DCE W2 = RTS/CTS delay XW2A = RS-232 0 10 30 ms interface Loopback RX A Switch RX A TX A...
Page 16
FOM LINE DRIVER—ST AND S M When in 2-wire, this is the time that the driver remains enabled after the TX of the last data bit. Delays are: A = 7 ms B = 2 ms C = 0.7 ms XW2B = RS-485 D = 0.15 ms interface...
Page 17
FOM LINE DRIVER—ST AND S M S5 set to A (20mA) XW2C = 20-mA interface 20-mA Terminal Block Loopback RX A Switch RX A TX A TX A RX B TX B RS-232 Slave Master Network RX B 20mA RS-485 TX B RS-232 S2 and S3...
FOM LINE DRIVER—ST AND S M 6. Troubleshooting 6.1 Application Problems If you’re having a problem with your application, reread the manual. Make sure you’ve selected the appropriate switches for the interface you chose. If your Line Driver is still not working properly, fill out an application diagram (found on pages 19, 21, and 23).
Page 19
FOM LINE DRIVER—ST AND S M Application Diagram forms are found on pages 19, 21, and 23. You may be asked to fax your diagram to the Technical Support department. Use scissors to remove the page.
Page 20
FOM LINE DRIVER—ST AND S M Local Node Remote Node NOTE NOTE 0 = Open or Off 0 = Open or Off 1 = Closed or On 1 = Closed or On...