System Operation; Switch On - Alpha ESS Storion-SMILE5 Installation, Operation & Maintenance Manual

Energy storage system ess
Table of Contents

Advertisement

Step 3: In the password input interface,
enter the password code "0001", confirm
entering the setting interface;
Step 5: Set the communication address and communication baud rate in the
communication setting interface. When the meter is used as the Grid meter, the
address is set to "005". When it is used as the grid-connected electromechanical
meter, the address is set to "006". The baud rate is set to 9600;
Step 6:After the meter is set, you need to activate the CT ratio on the display;

System Operation

3.1 Switch on

System shall be turned on in the correct sequence to avoid any damage.
___________________________________________________________________
System Operation
Step 4: In the setting interface, select
the
"Comm"
communication setting interface;
Alpha ESS Co., Ltd.
Your Smart Energy
option
to
enter