Routine Maintenance; Maintenance Plan; Operating Environment; Equipment Cleaning - Alpha ESS Storion-SMILE5 Installation, Operation & Maintenance Manual

Energy storage system ess
Hide thumbs Also See for Storion-SMILE5:
Table of Contents

Advertisement

Battery Short-circuit Current
Battery Type
Battery Cell Number
* Under specific test conditions.
** When the temperature is below 0 ° C or above 40 ° C, the performance will be limited.

Routine Maintenance

7.1 Maintenance Plan

Check if wire connection loose.
Check if cables aged/damaged.
Check if cable insulating ribbon drop.
Check if cable terminal screw loose, any overheat sign.
Check if ground connection is well.
7.1.1

Operating Environment

(Every half year)
Carefully observe whether the battery system equipment is ineffective or damaged;
When the system is running, listen to any part of the system for abnormal noise;
Check whether the voltage, temperature and other parameters of the battery and other
equipment parameters are normal during system operation;
7.1.2

Equipment Cleaning

(Every six months to one year, depending on the site environment and dust content,
etc.)
Ensure that the ground is clean and tidy, keep the maintenance access route
unblocked, and ensure that the warning and guiding signs are clear and intact.
Monitor the temperature of the battery module and clean the battery module if
necessary.
7.1.3

Cable, Terminal and Equipment Inspection

(Every six months to one year)
Check if the cable connection is loose.
Check whether the cable is aging or damaged.
Check whether the cable tie of the cable has fallen off.
___________________________________________________________________
Routine Maintenance
200A
LFP (LiFePO4)
32 (2P16S)
Alpha ESS Co., Ltd.
Your Smart Energy