Figure 72 System Mode Setting Interface
Step 10: Click Function-System Mode to
set system mode: DC, AC, Hybrid.
Figure 74 Force Charge Setting Interface
Step 12: If you want to use force charge,
sett Enable here.
Figure 76 UPS Reserve SOC Setting Interface
Step 14: Set the UPS Reserve SOC, it
means how much battery energy to keep
for UPS function.
Figure 78 Date&Time Setting Interface
Step 16: Click System in the setting
menu. Click Date &Time and set up the
date and time.
NOTE: It is needed to set the following 3 parameters for manual mode:
IP Address: IP address;
___________________________________________________________________
EMS Introduction and Set up
Step 11: Click the mode then set up work
mode.(self-use or force time charge)
Figure 75 Force Charge Time Setting Interface
Step 13: Set the charge and discharge
time.
Step 15: Click Safety in the setting
menu. Set safety standard.
AS4777 for Australia, ARN4105 for
Germany, CEI0_21 for Italy, G83_2 for
Great Britain
Step17: Click Ethernet to set the IP
address. DHCP mode means that setup
IP address is set up automatically.
If you want to set up the IP address
manually, please choose manual mode.
Alpha ESS Co., Ltd.
Your Smart Energy
Figure 73 Work Mode Setting Interface
Figure 77 Safety Setting Interface
Figure 79 Ethernet interface