Monitor Function - gefran SIEIDrive ADV100 Functions Description And Parameters List

Field oriented vector
Hide thumbs Also See for SIEIDrive ADV100:
Table of Contents

Advertisement

10 – MONITOR FUNCTION
Menu
PAR
Description
10.1
930
Reference 0 thr
Setting of the threshold for recognition of the speed = 0 reference. The value is valid for both directions of rotation.
Menu
PAR
Description
10.2
932
Reference 0 delay
Setting of the delay in milliseconds after which the reference = 0 reached signal is enabled.
Menu
PAR
Description
10.3
940
Speed 0 thr
Setting of the threshold for recognizing speed value = 0. The value is valid for both directions of rotation.
Menu
PAR
Description
10.4
942
Speed 0 delay
Setting of the delay in milliseconds after which the speed = 0 reached signal is enabled.
When the motor reaches a speed that is below the zero speed threshold, it stops and the
ADV100 • Functions description and parameters list
UM
Type
FB BIT
rpm
INT16
UM
Type
FB BIT
ms
UINT16
UM
Type
FB BIT
rpm
INT16
UM
Type
FB BIT
ms
UINT16
Def
Min
30
0
Def
Min
400
0
Def
Min
30
0
Def
Min
400
0
Max
Acc
Mod
CALCI
RW
FVS
Max
Acc
Mod
10000
RW
FVS
Max
Acc
Mod
CALCI
RW
FVS
Max
Acc
Mod
10000
RW
FVS
n = 0
LED lights up.
39

Hide quick links:

Advertisement

Table of Contents
loading