gefran SIEIDrive ADV100 Functions Description And Parameters List page 102

Field oriented vector
Hide thumbs Also See for SIEIDrive ADV100:
Table of Contents

Advertisement

Menu
PAR
Description
22.10.5 3328 Energysave trqband 2
This parameter is used to set a percentage used to calculate a range around the torque current the moment output
voltage reduction is aborted. The torque current is saved at the end of the voltage reduction phase. if the torque
current is not within the calculated range, due to a change in the load while functioning at low voltage, the output
voltage requested by the V/f curve must be restored.
Menu
PAR
Description
22.10.6 3340 Energysave out
This parameter is used to read the request to reduce the output voltage.
102
UM
Type
FB BIT
perc
FLOAT
UM
Type
FB BIT
FLOAT 16/32BIT
Def
Min
10.0
0.0
Def
Min
0.0
0.0
ADV100 • Functions description and parameters list
Max
Acc
Mod
100.0
ERWS _V_
Max
Acc
Mod
1.0
ER
_V_