gefran SIEIDrive ADV100 Functions Description And Parameters List page 107

Field oriented vector
Hide thumbs Also See for SIEIDrive ADV100:
Table of Contents

Advertisement

23.3.31 4094 Fieldbus M->S8 mon
23.3.35 4104 Fieldbus M->S9 mon
23.3.39 4114 Fieldbus M->S10 mon
23.3.43 4124 Fieldbus M->S11 mon
23.3.47 4134 Fieldbus M->S12 mon
23.3.51 4144 Fieldbus M->S13 mon
23.3.55 4154 Fieldbus M->S14 mon
23.3.59 4164 Fieldbus M->S15 mon
23.3.63 4174 Fieldbus M->S16 mon
The value received from the bus is displayed. This parameter must be associated with the src parameter to enable
the M->S channel.
The user may modify the M->S and by S->M sys parameters. The consistency of the sys with the parameter as-
signed to the channel is checked.
A Fieldbus M->S X Mon parameter can only be assigned to a single "src". If assigned to more than one src,
an error signal is generated during fieldbus initialization.
Menu
PAR
Description
23.3.4 4026 Fieldbus M->S1 div
23.3.8 4036 Fieldbus M->S2 div
23.3.12 4046 Fieldbus M->S3 div
23.3.16 4056 Fieldbus M->S4 div
23.3.20 4066 Fieldbus M->S5 div
23.3.24 4076 Fieldbus M->S6 div
23.3.28 4086 Fieldbus M->S7 div
23.3.32 4096 Fieldbus M->S8 div
23.3.36 4106 Fieldbus M->S9 div
23.3.40 4116 Fieldbus M->S10 div
23.3.44 4126 Fieldbus M->S11 div
23.3.48 4136 Fieldbus M->S12 div
23.3.52 4146 Fieldbus M->S13 div
23.3.56 4154 Fieldbus M->S14 div
23.3.60 4166 Fieldbus M->S15 div
23.3.64 4176 Fieldbus M->S16 div
The Div M->Sx fieldbus parameters can be used to increase the resolution of the datum sent on the bus to the drive
in the corresponding channel in EU and EU_float exchange mode. The parameter value is used by the drive as the
divider of the incoming datum, so that a number with decimal digits can be transferred.
N.B.: You must check the size in bits of the datum that is sent to make sure that the maximum value in bits fits in a
.
Example:
ADV100 • Functions description and parameters list
INT32 32
INT32 32
INT32 32
INT32 32
INT32 32
INT32 32
INT32 32
INT32 32
INT32 32
UM
Type
FLOAT
FLOAT
FLOAT
FLOAT
FLOAT
FLOAT
FLOAT
FLOAT
FLOAT
FLOAT
FLOAT
FLOAT
FLOAT
FLOAT
FLOAT
FLOAT
16-bit integer. For example, if specifying the divider as "Fieldbus M->Sn div" = 1000, the maxi-
mum value that can be used for the exchanged datum is 32.768 (32768/1000).
Div M->Sx fieldbus = 10, M->S1 fieldbus par = Ramp ref src 1, Sys M->S1 fieldbus = Eu. If
the PLC sends the decimal value 1000 on the first word the value of ramp ref 1 on the drive is
1000/10 = 100.
0
0
0
0
0
0
0
0
0
FB BIT
Def
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Min
Max
1.0
1000.0
1.0
1000.0
1.0
1000.0
1.0
1000.0
1.0
1000.0
1.0
1000.0
1.0
1000.0
1.0
1000.0
1.0
1000.0
1.0
1000.0
1.0
1000.0
1.0
1000.0
1.0
1000.0
1.0
1000.0
1.0
1000.0
1.0
1000.0
ER
FVS
ER
FVS
ER
FVS
ER
FVS
ER
FVS
ER
FVS
ER
FVS
ER
FVS
ER
FVS
Acc
Mod
ERW FVS
ERW FVS
ERW FVS
ERW FVS
ERW FVS
ERW FVS
ERW FVS
ERW FVS
ERW FVS
ERW FVS
ERW FVS
ERW FVS
ERW FVS
ERW FVS
ERW FVS
ERW FVS
107