21.19
2474 Damping threshold 2
Setting of the second damping gain regulation threshold. These settings are usually effective for intermediate fre-
quencies and make it possible to limit motor oscillations.
Menu
PAR
Description
21.20
2480 Vf min frequency
Setting of the minimum frequency in the V/f control mode. This represents the minimum output frequency, below
which frequency regulations are ineffective. It is not possible to go below this value, regardless of the reference that
has been set.
Menu
PAR
Description
21.21
2482 Vf min freq delay
Setting of the delay for the minimum frequency signal in the V/f control mode.
Menu
PAR
Description
21.22
2490 Dig Vf scale
Setting of a digital multiplier factor for the drive output voltage in the V/f mode.
Menu
PAR
Description
21.23
2492 Vf scale src
Selection of the origin (source) of the signal to be used to set a multiplier factor for the drive output voltage. The as-
sociable functions are listed in the "L_REF" selection list.
ADV100 • Functions description and parameters list
UM
Type
FB BIT
Hz
INT16
UM
Type
FB BIT
Hz
FLOAT
UM
Type
FB BIT
ms
UINT16
UM
Type
FB BIT
FLOAT 16/32
UM
Type
FB BIT
LINK
16/32
Def
Min
30
5
Def
Min
1.0
0.2
Def
Min
800
0
Def
Min
1.0
0.0
Def
Min
3374
0
Max
Acc
Mod
100
ERW V
Max
Acc
Mod
5.0
ERW V
Max
Acc
Mod
5000
ERW V
Max
Acc
Mod
1.0
ERWZ V
Max
Acc
Mod
16384
ERW V
81