gefran SIEIDrive ADV100 Functions Description And Parameters List page 26

Field oriented vector
Hide thumbs Also See for SIEIDrive ADV100:
Table of Contents

Advertisement

maximum value set in the Full scale speed (5.22). On the other hand, the deceleration times (6.2, 6.4, 6.6, 6.8
) are expressed as the time necessary to bring the frequency from the maximum value set in the Full scale speed
(5.22) parameter to zero. Each of the 4 available ramp selections can be selected using one or two digital inputs
programmed as Multi ramp sel.
Menu
PAR
Description
6.9
720
Ramp type
This parameter defines the ramp shape (linear/S-shape). It can only be modified with the drive disabled.
0 Linear
1 S-Shape
2 Bypass
3 Off
6.1
0 = Linear
When linear ramps are set (Linear) the motor speed varies in a way that is directly in proportion to the
frequency.
When S-shape ramps are set (S-Shape) it is possible to avoid sudden mechanical variations in the system at the
beginning and end of the acceleration and deceleration phase.
The ramp time, meaning the time necessary to accelerate from zero to the maximum frequency value
set, is given by the sum of the linear ramp time and that of the associated Jerks (see par. 6.13 – 6.20).
The Bypass excludes the ramp circuit and the reference is brought directly to the speed regulator input.
With Off the ramp reference is set to zero.
Menu
PAR
Description
6.10
722
Multi ramp sel 0 src
6.11
724
Multi ramp sel 1 src
1 or 2 digital inputs can be used to select one of the 4 available sets of ramps.
The origin (source) of the command to enable the ramp selection function can be selected from the "L_DIGSEL2"
selection list.
The following table describes the ramp selection procedure:
Enabled ramp time
Acceleration time 0
Deceleration time 0
Acceleration time 1
Deceleration time 1
Acceleration time 2
Deceleration time 2
Acceleration time 3
Deceleration time 3
26
UM
Type
FB BIT
ENUM
f
6.13
6.2
T
ACC TIME
UM
Type
FB BIT
LINK
LINK
Multi ramp sel 0
0
1
0
1
Def
Min
Linear
0
6.13
6.14
DEC TIME
1 = S-Shape
Def
Min
6000
0
6000
0
Multi ramp sel 1
0
0
1
1
ADV100 • Functions description and parameters list
Max
Acc
Mod
3
ERWZ FVS
6.14
t
Max
Acc
Mod
16384
ERWZ FVS
16384
ERWZ FVS

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents