Configuration - Baumer CiA DS-301 Manual

Absolute encoder with canopen
Table of Contents

Advertisement

Changing the baud rate
The baud rate can be changed in the object 2100h. An index is written into the object, not the effective baud
rate.
Baud rate
0
10 kBaud
1
20 kBaud
2
50 kBaud
3
100 kBaud
4
125 kBaud
5
250 kBaud
6
500 kBaud
7
800 kBaud
8
1000 kBaud
The baud rate now still has to be saved using object 1010h-1h. On next initialization, the encoder/converter
logs on to the new baud rate. However, before this the baud rate of the master should be changed.
5.2

Configuration

Position setting
The value is transmitted:
COB ID
DLC Command
600h+node ID
8
Conformation:
COB ID
DLC Command
580h+node ID
8
Changing the sense of rotation and scaling
The sense of rotation can be set to CW (clockwise) or CCW (counterclockwise). In addition, the scaling can
be switched on or off in the same object (6000h). With the scaling switched on, the set resolutions are used.
However, if the scaling is switched off, the encoder/converter works with the maximum resolution settings
(6501h and 6502h).
Bit 0:
0 -> CW (clockwise)
1 -> CCW (counterclockwise)
Bit 2:
0 -> Scaling off
1 -> Scaling on
Counterclockwise rotation and scaling on:
COB ID
DLC Command
600h+node ID
8
Confirmation:
COB ID
DLC Command
580h+node ID
8
BUDE_Manual-CANopen_EN.doc
23.10.2012/bja
Object L
23h
03h
Object L
60h
03h
Object L
23h
00h
Object L
60h
00h
Object H
Subindex Data 0
60h
0h
a
Object H
Subindex Data 0
60h
0h
0h
Object H Subindex Data 0 Data 1 Data 2 Data 3
60h
0h
5h
Object H
Subindex Data 0 Data 1
60h
0h
0h
47/55
Data 1 Data 2 Data 3
b
c
d
Data 1 Data 2 Data 3
0h
0h
0h
x
x
x
Data 2 Data 3
0h
0h
0h
Baumer Hübner GmbH
Berlin, Germany