Baumer CiA DS-301 Manual page 48

Absolute encoder with canopen
Table of Contents

Advertisement

Changing singleturn resolution
In object 6001h, the singleturn resolution can be configured. For example 1024 (10bit) steps per revolution
(1024 = 400h):
COB ID
DLC Command
600h+node ID
8
Confirmation:
COB ID
DLC Command
580h+node ID
8
Changing the overall resolution
In object 6002h, the overall resolution can be set. The overall resolution and the singleturn resolution result
in the number of revolutions. Example: The singleturn resolution is set at 10 bit (1024 steps) and the overall
resolution at 22 bit (4194304), resulting in 4096 (12bit) revolutions of 1024 (10bit) steps each.
Setting the overall resolution to 4194304 (4194304 = 400000h)
COB ID
DLC Command
600h+node ID
8
Confirmation:
COB ID
DLC Command
580h+node ID
8
Saving the setting in the EEPROM
Object 1010h initiates the save routine for the objects below in the non-volatile memory (EEPROM). In order
to prevent unintentional saving, the message "Save" must be written in Subindex 1.
COB ID
DLC Command
600h+node ID
8
COB ID
DLC Command
580h+node ID
8
BUDE_Manual-CANopen_EN.doc
23.10.2012/bja
Object L
23h
01h
Object L
60h
01h
Object L
23h
02h
Object L
60h
02h
Object L
23h
10h
Object L
60h
10h
Object H
Subindex Data 0
60h
0h
00h
Object H
Subindex Data 0
60h
0h
0h
Object H
Subindex Data 0
60h
0h
00h
Object H
Subindex Data 0
60h
0h
0h
Object H
Subindex Data 0
10h
01h
73 's'
Object H
Subindex Data 0
10h
01h
0h
48/55
Data 1 Data 2 Data 3
04h
00h
00h
Data 1 Data 2 Data 3
0h
0h
0h
Data 1 Data 2 Data 3
00h
40h
00h
Data 1 Data 2 Data 3
0h
0h
0h
Data 1 Data 2 Data 3
61 'a'
76 'v'
65 'e'
Data 1 Data 2 Data 3
0h
0h
0h
Baumer Hübner GmbH