1. Installation
1.2
Setting the DIL switches on the field bus node
1.2.1 Removing and fitting the cover for the DIL switches
Removing
Fitting
1−8
In order to set the CPX field bus node, you must remove the
cover over the DIL switches.
Caution
The CPX field bus node contains electrostatically sensitive
components.
Do not touch the electrical contacts of the components.
·
Observe the regulations for handling electrostatically
·
sensitive components.
In this way you will avoid damage to the electronics.
In order to set the CPX field bus node, you must remove the
cover over the DIL switches.
1. Switch off the power supply.
2. Unscrew the two fastening screws on the switch cover.
3. Remove the cover.
1. Place the cover carefully onto the node.
Please note
Make sure that the seal is seated correctly.
·
2. Tighten the fastening screws at first by hand and then
with 0.4 Nm.
Festo P.BE−CPX−FB14−E N en 0308a