Settings Of The Dil Switches On The Bus Node; Removing And Fitting The Cover Over The Dil Switches - Festo CPX-FB38 Electronic Manual

Cpx bus node, network protocol ethercat
Hide thumbs Also See for CPX-FB38:
Table of Contents

Advertisement

1. Installation
1.2

Settings of the DIL switches on the bus node

1.2.1 Removing and fitting the cover over the DIL switches

Festo P.BE−CPX−FB38−EN en 0804NH
To set the CPX bus node, the cover for the DIL switches must
be removed.
Caution
The CPX bus node contains electrostatically sensitive
components.
Therefore, do not touch any contacts.
·
Observe the handling specifications for electrostatically
·
sensitive components.
You avoid malfunctions of and damage to the electronics by
doing so.
You need a screwdriver in order to remove or fit the cover.
Please note
Observe the following instructions when removing or
fitting the cover:
Disconnect the power supply before removing the cover.
·
Make sure that the seal is seated correctly when fitting
·
the cover.
Tighten the two fastening screws at first by hand and
·
then with max. 0.4 Nm.
1−7