Festo CPX-FB14 Electronic Manual page 125

Cpx terminal
Hide thumbs Also See for CPX-FB14:
Table of Contents

Advertisement

3. Diagnosis
M (Modify) parametrizing modified or Force active
LED (yellow)
Sequence
ON
OFF
LED is out
ON
OFF
LED flashes
ON
OFF
LED lights up
Tab. 3/4:
Messages of the LED M
Festo P.BE−CPX−FB14−E N en 0308a
Status
System start with default
parametrizing (factory set
ting) and current CPX
equipment status is set;ex
ternal parametrizing is
possible (pre−setting).
Force is active
System start with saved
parametrizing and saved
CPX equipment status is
set;
Parameters and CPX equip
ment status are saved re
manently; external
parametrizing is blocked.
Meaning/fault treatment
None
The Force function is enabled (see
system parameter Force mode; func
tion no. 4402).
Caution when replacing CPX terminals
with saved parametrizing.
With these CPX terminals, the parame
trizing is not automatically restored by
the higher−order PLC/IPC after re
placement. In these cases, check be
fore replacement to see which set
tings are required and carry out these
settings.
3−9