Appendix E. Sabbath Mode; E1. General Guidance; E2. Connection; E3. Arming The System By Sabbath Clock - DSC WP8010 Installer's Manual

Hide thumbs Also See for WP8010:
Table of Contents

Advertisement

3. WP8010 INSTALLATION

APPENDIX E. Sabbath Mode

E1. General Guidance

The Sabbath Mode allows you to use the alarm system without violating the Sabbath. The basic feature of this alarm
system is that the PIR sensors are not activated during Disarm mode.
The method of installation, as illustrated in the drawing below, is used in order to prevent transmission from the
magnetic contact device. The PG9945 device is used only as a transmitting device to report the status of the door to
the control panel. A wired magnetic contact is connected to the input of the PG9945 device and an open/close switch is
connected in parallel to the PG9945 input.
Note: Before the Sabbath, closing the circuit neutralizes the detector's magnet. You can use the front door without
violating the Sabbath. On the Sabbath day itself, you can open the switch to allow the door to be protected. This
operation is permitted on the Sabbath and also when the control panel is armed.

E2. Connection

1. Enroll an PG9945 to the WP8010/WP8030 control panel (see section 5.4.2).
2. Configure the "Input #1" setting option of the PG9945 to "Normally Closed" (refer to the PG9945 Installation
Instructions, section 2.3).
3. Connect to the PG9945 a wired magnetic contact to be installed on the door and that is operated by opening/closing
the door (see drawing below).
4. An open/close switch must be connected in parallel to the input of the PG9945.
Wiring Setup
A. PG9945 device
B. Wired magnetic contact
C. Fixed frame
D. Moving part
E. Open/close switch
E1. Closed
E2. Open

E3. Arming the System by Sabbath Clock

1. Enroll an PG9945 to the WP8010/WP8030 control panel (see section 5.4.2).
2. Configure the Zone Type to "11.Arming Key" (see section 5.4.2)
3. Configure the "Input #1" setting option of the PG9945 to "Normally Open" (refer to the PG9945 Installation
Instructions, section 2.3).
4. From the "03:CONTROL PANEL" menu, configure the "09:ARMING KEY" setting option to "arm HOME" (see
section 5.5.2).
Note: When the alarm system is armed at night by a Sabbath clock, the open / close switch must be opened when the
door is closed.
92
D-306233 CUSDOC PM-10/30 V18 DSC TRIPLE EN INST

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wp8030

Table of Contents