Appendix A: Reporting Codes

The following tables contain Contact ID and Automatic SIA for-
mat reporting codes. For more information on reporting code
formats and notes about individual reporting codes, (See Sec-
tion 5.6 Communicator Programming PWS Sect 6).
Contact ID
The first digit (in parentheses) will automatically be sent by the
control. The second two digits are programmed to indicate spe-
cific information about the signal.
For example, if zone 1 is an entry/exit point, you could program
the event code as [34]. The central station would receive the
following:
*BURG - ENTRY/EXIT - 1
where the "1" indicates which zone went into alarm.
Section #
Reporting Code
[320]-[323]
Zone Alarms
[324]-[327]
Zone Restorals
[328]
Duress Alarm
[328]
Opening After Alarm
[328]
Recent Closing
[328]
Zone Expander Supervisory
Alarm/Rest.
[328]
Cross Zone (Police Code)
Alarm
[328]
Burglary Not Verified
[328]
[329]
[F] Key Alarm/Rest.
[329]
[A] Key Alarm/Rest.
[329]
[P] Key Alarm/Rest.
[329]
Aux Input Alarm/Rest
[330]-[337]
Zone Tamper/Restoral
[338]
General System Tamper/
Rest.
[338]
Keypad Lockout
[339-341]
Closings
[341]
Partial Closing
[341]
Special Closing
[341]
Late to Close
[342-344]
Openings
[344]
Auto-arm Cancellation
* A/R = alarms/restorals; T/R = tampers/restorals; O/C = openings/closings; MA/R = miscellaneous alarms/restorals; T = test transmissions
Code Sent When...
Zone goes into alarm
Alarm condition has been restored
Duress code entered at keypad
System disarmed with alarm in memory
Alarm occurs within two minutes of system arming
Panel loses/restores supervisory transmission over the Key-
bus from zone expansion modules, or keypads with zone
inputs
Two zones on the same partition go into alarm during any
given armed-to-armed period (incl. 24Hr zones)
Keypad fire alarm (alarm and restore rep. codes sent
together)
Keypad auxiliary alarm (alarm and restore rep. codes sent
together)
Keypad panic alarm (alarm and restore rep. codes sent
together)
Option#23/24: a panic button wired to PGM 2 is pressed/
access code is entered
Option #04: a 2-wire smoke detector wired to PGM 2 goes
into alarm/alarm is cleared.
Zone is tampered / tamper condition restored
Enrolled module with tamper inputs has a tamper alarm/all
module tampers restored
Maximum number of incorrect access codes has been
entered at a keypad
System armed (user 01-34, 40-42 indicated)
One or more zones bypassed when system armed
Closing (arming) using one of the following methods: quick
arm, auto arm, keyswitch, function key, maintenance code,
DLS software, wireless key
Whenever the auto-arm prealert sounds (if the Late to
Close option is enabled)
System disarmed (user 01-34, 40-42 indicated)
Auto-arm cancelled
SIA Format - Level 2 (Hardcoded)
The SIA communication format used in this product follows the
level 2 specifications of the SIA Digital Communication Standard
- October 1997. This format will send the Account Code along
with its data transmission. The transmission will look similar to
the following at the receiver:
N Ri01
N
=
Ri01
=
BA
=
01
=
NOTE: A system event will use the Area Identifier Ri00.
Dialer
Direction*
A/R
A/R
A/R
A/R
A/R
A/R
A/R
A/R
A/R
A/R
A/R
A/R
A/R
T/R
T/R
T/R
O/C
O/C
O/C
O/C
O/C
O/C
** UU = user number (user01-42); ZZ = zone number (01-64)
R e p o r t i n g C o d e s
BA 01
New Event
Partition /Area Identifier
Burglary Alarm
Zone 1
Automatic
SIA Auto Rep
Contact ID
Codes**
Codes
See Table 3
See Table 3
(1) 21
HA-00
(4) A6
OR-00
(4) 59
CR-00
(1) 43
UA-00/UH-00
(1) 4A
BM-00/BV-00
(3) 78
XM-00
(1) 15
FA-00/FH-00
(1) AA
MA-00/MH-00
(1) 2A
PA-00/PH-00
(1) 4A
UA-99/UH-99
(1) 11
FA-99/FH-99
(1) 44
TA-ZZ/TR-ZZ
(1) 45
TA-00/TR-00
(4) 21
JA-00
(4) A2
CL-UU
(4) 7A
CG-ZZ
(4) AA
CL-00
(4) A4
CI-00
(4) A2
OP-UU
(4) A5
CE-00
55