11:CANCEL ALARM
The WP8010/WP8030 can be configured to provide a "Cancel Alarm" time window that starts
upon reporting an alarm to the Monitoring Station. If the user disarms the system within that
"cancel alarm" time, a "cancel alarm" message is sent to the Monitoring Station indicating that
the alarm was canceled by the user.
Options: not active (default in USA); in 1/5 (default)/15/60 minute(s) and in 4 hours.

5.14.5 CP01 Setup

13:OPERATION MOD
Enter the "04:CP01 SETUP" menu to configure its settings.
Option
01:DISARM OPTION
03:END EXIT MODE
05:CONFIRM ALARM
07:RPT CNFM ALRM
08:ENTRY DELAY 1
09:ENTRY DELAY 2
10:ABORT TIME
1
Applies only when the keyfob is defined as "skip exit delay" (for further details, see the keyfob's User's Guide)
D-306233 CUSDOC PM-10/30 V18 DSC TRIPLE EN INST
Configuration Instructions
  
CP01 SETUP
Configuration Instructions
Certain regulations require that when the system is armed in AWAY mode, it may not be
disarmed from the outside of the house (such as by keyfobs) before entering the protected
premises and activating an "Entry Delay" zone. To answer this requirement, the
WP8010/WP8030 provides you with the following configurable options to disarm the system:
any time (default), the system can be disarmed at all times from all devices.
on entry wrless - During entry delay, the system can be disarmed only using keyfob or prox
operated devices.
entry + away kp. - During entry delay by code, the system can be disarmed only using
WP8010/WP8030 panel keypad.
on entry all. - During entry delay, the system can be disarmed using keyfobs or by code
using the WP8010/WP8030 panel keypad.
Define how the exit delay is terminated or restarted according to the following options:
restart+arm home (default) – During exit delay if the door was not opened, the alarm
system will be armed HOME instead of armed AWAY.
restart>reentry - Exit delay restarts when the door is reopened during exit delay. The restart
occurs once only. Restarting the exit delay is helpful if the user re-enters immediately after
going out to retrieve an item that was left behind.
door/fob/timer - When the door is closed, by pressing the AUX button on the keyfob
when the exit delay has expired, whichever first.
fob/timer - By pressing the AUX button on the keyfob
whichever first.
Define a specific time period that if 2 successive alarms occur, the second alarm will be
considered as a confirmed alarm, (see RPT CNFM ALRM below).
Options: disable (default in USA); in 30/45/60(default)/90 minutes
Define whether the system will report a confirmed alarm.
report disabled (default) - The system will not report a confirmed alarm.
report enabled - The system will report a confirmed alarm.
Two different entry delays allow the user to enter the protected site (while the system is in
the armed state) via 2 specific doors and routes without causing an alarm.
Following entry, the user must disarm the control panel before the entry delay expires. Slow-
rate warning beeps start sounding once the door is opened, until the last 10 seconds of the
delay, during which the beeping rate increases. Locations No. 1 (entry delay 1) and 2 (entry
delay 2) allow you to program the length of these delays.
Options: 30 (default)/45/60 seconds; 3/4 minutes
The WP8010/WP8030 can be configured to provide a delay before reporting an alarm to the
monitoring station (not applicable to alarms from FIRE, 24H SILENT, EMERGENCY, GAS
FLOOD and TEMPERATURE zones). During this delay period, the external siren will not
sound and the alarm is not reported. If the user disarms the system within the delay time, the
alarm is aborted.
Options: in 15 (default)/30/45 seconds