3. WP8010 INSTALLATION
Option
05:DUAL REPORT
11:RCVR1 ACCOUNT
12:RCVR2 ACCOUNT
Master Installer only
16:PSTN/GSM RCV1
17:PSTN/GSM RCV2
Master Installer only
21:IP RCVR 1
22:IP RCVR 2
Master Installer only
26:SMS RCVR 1
27:SMS RCVR 2
Master Installer only
52
Configuration Instructions
Note:
When Cellular channel is selected, the order of priority will be GPRS (IP) channel
first, then GSM voice channel and lastly SMS channel, provided that these
channels have been enabled in section 5.6.3.
Define whether or not to report events using PSTN and broadband, PSTN and cellular or
broadband and cellular communication channels.
Options: disable (default); PSTN & broadband; PSTN & cellular; broadband & cell.
st
Enter the respective 1
Account (subscriber) number (11:RCVR 1 ACCOUNT) that will identify
your specific alarm system to the 1
nd
2
Account (subscriber) number (12:RCVR 2 ACCOUNT) that will identify the system to the 2
Monitoring Station (designated as RCVR2 or RCV2). Each of the Account numbers consists of
6 hexadecimal digits.
To enter Hexadecimal digits, use the following table:
Entering Hexadecimal Digits
0.....9
Digit
0.....9
Keying
The WP8010/WP8030 can be programmed to report the event messages defined in the Report
Events option (option 01) to two Alarm Format Receivers via PSTN telephone line and/or GSM
analog voice channel (if equipped with GSM module), using standard PSTN alarm formats (i.e.
SIA and/or Contact-ID approved by UL, and Scancom not for UL). The reporting format is
defined in the "PSTN Report Format" option (option 41).
Enter the two respective telephone numbers (including area code – maximum 16 digits) of
the Alarm Format Receiver 1 located at the 1
alarm format Receiver 2 located at the 2
Note: If any of the phone numbers programmed herein contain an area code identical to the
area code of the PSTN telephone line to which the system is connected, you should refer to
the "AREA CODE" option in section 5.6.2.and act as instructed there.
Digit
Keying
Digit Significance
[#]  [0]
A
The dialer waits 10 seconds or waits for dial tone, whichever comes first
and then dials. Applicable only at the 1
[#]  [3]
D
The dialer waits 5 seconds for dial tone and goes on hook if none is
received. Applicable only at the 1
[#]  [4]
E
The dialer waits 5 seconds. Applicable only in the middle of the number.
To move the cursor and clear digits, use the "String Editor's" keys as described in the
table in section 5.8.1.
If equipped with GSM or Broadband/PowerLink modules, the WP8010/WP8030 can be
programmed to report the event messages defined in Report Events option (option 01) to two IP
Receivers, DSC PowerManage model. IP reporting can be performed via GPRS (IP) channel
using SIA IP format or via Broadband IP channel using SIA IP or DSC PowerNet format.
Enter the two IP addresses (000.000.000.000) of the IP Receiver 1 located at the 1
Station (21:IP RCVR 1) and IP Receiver 2 located at the 2
If equipped with GSM module, the WP8010/WP8030 can be programmed to report the event
messages defined in Report Events option (option 01) to two SMS Receivers via the GSM
SMS channel using a special SMS text format. For further details concerning the SMS text
format please contact DSC.
Enter the two telephone numbers (including area code – maximum 16 digits).of the SMS
Receiver 1 located at the 1
nd
located at the 2
Monitoring Station (27:SMS RCVR 2).
Notes:
1. To enter the international prefix (
2. SMS is not sent to UL/ULC listed Monitoring Station receivers. This is a supplementary
feature of the WP8010/WP8030.
st
Monitoring Station (designated as RCVR1 or RCV1) and a
A
B
C
[#]  [0]
[#]  [1]
[#]  [2]
st
Monitoring Station (16: PSTN/GSM RCV1) and
nd
Monitoring Station (17: PSTN/GSM RCV2).
st
Monitoring Station (26:SMS RCVR 1) and SMS Receiver 2
st
digit – key-in [#]
) at the 1
D-306233 CUSDOC PM-10/30 V18 DSC TRIPLE EN INST
D
E
[#]  [3]
[#]  [4]
st
digit.
st
digit.
nd
Monitoring Station (22:IP RCVR 2).
[1].
nd
F
[#]  [5]
st
Monitoring