PowerSeries - PC1616/PC1832/PC1864

Appendix A: Reporting Codes

The following tables contain Contact ID and Automatic SIA format reporting codes. For more information on reporting code formats and notes about
individual reporting codes.
Contact ID
The first digit (in parentheses) will automatically be sent by the control. The second two digits are programmed to indicate specific information about
the signal. For example, if zone 1 is an entry/exit point, you could program the event code as [34]. The central station would receive the following:
*BURG - ENTRY/EXIT - 1 where the "1" indicates which zone went into alarm.
SIA Format - Level 2 (hard coded)
The SIA communication format used in this product follows the level 2 specifications of the SIA Digital Communication Standard - October 1997.
This format will send the Account Code along with its data transmission. The transmission will look similar to the following at the receiver:
NOTE: A system event will use the Area Identifier Ri00.
N Ri01 = BA 01
N = New Event
Ri01 = Partition /Area Identifier
Table 1: Reporting Codes
Section #
Reporting Code
[320]-[323]
Zone Alarms
[324]-[327]
Zone Restorals
[328]
Duress Alarm
[328]
Opening After Alarm
[328]
Recent Closing
[328]
Zone Expander Supervisory
Alarm/Rest.
[328]
Cross Zone (Police Code)
Alarm
[328]
Burglary Not Verified
[328]
Alarm Cancelled
[329]
[F] Key Alarm/Restoral
[329]
[A] Key Alarm/Restoral
[329]
[P] Key Alarm/Restoral
[329]
Aux Input Alarm/Rest
[330]-[337]
Zone Tamper/Restoral
[338]
General System Tamper/
Rest.
[338]
Keypad Lockout
[339-341]
Closings
[341]
Partial Closing
[341]
Special Closing
[341]
Late to Close
[341]
Exit Fault
[341]
Zone Unbypass
[341]
Zone Bypass
[342-344]
Openings
[344]
Auto-arm Cancellation
[344]
Special Opening
[345]-[346]
Battery Trouble/Rest.
[345]-[346]
AC Line Trouble/Rest.
[345]-[346]
Bell Circuit Trouble/Rest.
[345]-[346]
Fire Trouble/Rest.
[345]-[346]
Auxiliary Power Trouble/Rest. Aux voltage supply trouble/restoral
BA = Burglary Alarm
01 = Zone 1
Code Sent When...
Zone goes into alarm
Alarm condition has been restored
Duress code entered at keypad
System disarmed with alarm in memory
Alarm occurs within two minutes of system arming
Panel loses/restores supervisory transmission over the Keybus from
zone expansion modules, or keypads with zone inputs
Two zones on the same partition go into alarm during any given armed-
to-armed period (incl. 24Hr zones)
This event is transmitted when a second cross-zone alarm does not
occur within the cross-zoning time
Sent when the system is disarmed after an alarm, but before the expiry
of the alarm cancellation timer
Keypad fire alarm/restore (alarm and restore rep. codes sent together)
Keypad auxiliary alarm/restore (alarm and restore rep. codes sent
together)
Keypad panic alarm/restore (alarm and restore rep. codes sent
together)
Option#23/24: a panic button wired to PGM 2 is pressed/access code
is entered
Option #04: a 2-wire smoke detector wired to PGM 2 goes into alarm/
alarm is cleared
Zone is tampered / tamper condition restored
Enrolled module with tamper inputs has a tamper alarm/all module
tampers restored
Max. number of incorrect access codes has been entered at a keypad
System armed (user 01-32 indicated)
One or more zones bypassed when system armed
Closing (arming) using one of the following methods: quick arm, auto
arm, keyswitch, function key, maintenance code, DLS software,
wireless key
Whenever the Auto-arm prealert sounds (if the Late to Close option is enabled)
The Exit Fault pre-alert occurs and Entry Delay expires
When the user removes a bypass on a zone in [*][1], or when a force
armable zone is returned to service, zone unbypass status is
communicated.
Zone is bypassed
System disarmed (user 01-32 indicated)
Auto-arm cancelled
Opening (disarming) using one of the following methods: keyswitch,
maintenance code, DLS software, wireless key
PC1616/PC1832/PC1864 battery is low/battery restored
AC power to control panel is disconnected or interrupted/AC power
restored (Both codes follow AC Failure Comm. Delay)
Open or short circuit detected across bell terminals/bell circuit restored
Trouble occurs/restores on a fire zone
55
Automatic
Dialer
SIA Auto
Contact ID
Direction*
Rep Codes**
Codes
A/R
See
See Table 3
Tables 2 & 3
A/R
A/R
E(1)21-000
A/R
E(4)58-000
A/R
E(4)59-UUU
A/R
E(1)43-000/
UA-00/UH-00
R(1)43-000
A/R
E(1)39-000
BM-00/BV-00
A/R
E(3)78-000
A/R
E(4)A6-UUU
A/R
E(1)1A-000/
FA-00/FH-00
R(1)1A-000
A/R
E(1)AA-000/
MA-00/MH-00
R(1)AA-000
A/R
E(1)2A-000/
PA-00/PH-00
R(1)2A-000
A/R
E(1)4A-000/
UA-99/UH-99
A/R
R(1)4A-000
FA-99/FH-99
E(1)11-000/
R(1)11-000
T/R
E(3)83-ZZZ/
TA-ZZ/TR-ZZ
R(3)83-ZZZ
T/R
E(1)45-000/
ES-00/EJ-00
R(1)45-000
T/R
E(4)61-000
O/C
R(4)A1-UUU
O/C
E(4)56-000
O/C
R(4)AA-000
O/C
R(4)54-000
O/C
E(3)74-ZZZ
O/C
R(5)7A-ZZZ
O/C
E(5)7A-ZZZ
O/C
E(4)A1-UUU
O/C
E(4)55-000
O/C
E(4)AA-000
MA/R
E(3)A2-000/
YT-00/YR-00
R(3)A2-000
MA/R
E(3)A1-000/
AT-00/AR-00
R(3)A1-000
MA/R
E(3)21-000/
YA-99/YH-99
R(3)21-000
MA/R
E(3)73-000/
FT-99/FJ-99
R(3)73-000
MA/R
E(3)12-000/
YP-00/YQ-00
R(3)12-000
HA-00
OR-00
CR-00
BG-00
BC-00
JA-00
CL-UU
CG-00
CL-00
CI-00
EE-00
UU-ZZ
UB-ZZ
OP-UU
CI-00
OP-00