Advertisement

1. INTRODUCTION ................................................. 2
1.1 System Features .......................................... 2
3. WP8033 INSTALLATION .................................... 7
3.1 WP8033 Wiring Diagram .............................. 7
Bracket Mounting ............................................... 8
"K" in Figure 3.1) ................................................ 8
"B" in Figure 3.1) ................................................ 9
"L" in Figure 3.1) .............................................. 10
3.7 Installing the PLINK3 DSC ......................... 12
Figure 3.1) ......................................................... 13
3.9.1 Battery Insertion ................................. 16
D-306048
WP8033 Installer's Guide
WP8033
Version 18
Installer's Guide

Table of Contents

4.
5. MAINTENANCE ................................................. 19
APPENDIX A. Specifications ............................... 20
Operations by the keypad ................................... 23
4.1 WP8033 LED Indications ............................ 18
4.3 Using the Prox Tag ..................................... 19
5.2 Replacing the Backup Battery ................... 19
5.3 Fuse Replacement ...................................... 19
5.5 Annual System Check ................................ 19
A1. Functional ................................................... 20
A2. Wireless ...................................................... 20
A3. Electrical ..................................................... 20
A4. Communication .......................................... 21
A5. Physical Properties .................................... 21
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the WP8033 and is the answer not in the manual?

Questions and answers

Summary of Contents for DSC WP8033

  • Page 1: Table Of Contents

    APPENDIX B. Compliance with Standards ..22 3.9.1 Battery Insertion ......... 16 Quick User Guide to Main Alarm Control 3.9.2 Connect AC Power to the Unit ... 16 Operations by the keypad ........23 3.10 Closing the WP8033 Control Panel ..17 D-306048 WP8033 Installer's Guide...
  • Page 2: Introduction

    The system consists of the WP8033 control panel that does not include a built-in keypad and that operates in conjunction with a wireless keypad display device. The control panel accommodates all control circuitry and operation software for a programmable 64-zone alarm system, while the keypad display unit enables the installer and the user to enter their commands and provides visual and audible feedback.
  • Page 3 PowerG devices Installation Location. include a built-in link quality indicator. Choosing the mounting location is a quick and easy process. Supported in specific WP8033 variants (for further details, please contact your DSC representative). D-306048 WP8033 Installer's Guide...
  • Page 4 Installer’s Guide or the keypad User’s Guide Guard key-safe WP8033 is able to control a safe that holds 1. Connect the safe to the panel: see site keys that are accessible only to the site's section 3.8 Optional Expander Module...
  • Page 5 Camera Keypad Mirror Detector Motion Detector Two-way Keyfobs Safety Detectors WP8033 PGx9916 PGx9926 Smoke PGx9905 Smoke & Heat Temperature WK160 Keyprox Detector Detector Detector Sirens PGx9913 Carbon Monoxide (CO) Detector PGx9911 PGx9901 Outdoor Indoor Siren Siren D-306048 WP8033 Installer's Guide...
  • Page 6: Choosing The Installation Location

    2. CHOOSING THE INSTALLATION LOCATION To ensure the best possible mounting location of the WP8033 control panel, the following points should be observed:  The selected location should be approximately in the center of the installation site between all the transmitters, preferably in a hidden location.
  • Page 7: Wp8033 Installation

    3. WP8033 INSTALLATION Required tool: Philips screwdriver #2. WP8033 mounting process is shown in Figures 3.1 - 3.10. 3.1 WP8033 Wiring Diagram A. Expander Module Flat B. Wired Zone / Special C. Battery Connector D. ENROLL button Cable Siren Terminal Block E.
  • Page 8: Opening The Wp8033 Control Panel And Bracket Mounting

    3.2 Opening the WP8033 Control Panel and Bracket Mounting A. Mounting surface To Mount the Unit: 1. Release the screws B. Back unit 2. Remove the front cover C. 5 screws 3. Mark 5 drilling points on the mounting surface...
  • Page 9: Connecting Wired Zone And Siren (Detail "B" In Figure 3.1)

    F. Magnetic contact or any other contact (not a detector) G. Alarm N.C. Figure 3.4 – Wired Zone and Siren Wiring Wired zones can be enrolled in any zone in the WP8033- G2 control panel from 01 to 64 D-306048 WP8033 Installer's Guide...
  • Page 10: Gsm Module And Sim Installation (Detail "L" In Figure 3.1)

    IMPORTANT! Do not insert or remove SIM card when system is powered by AC power or backup battery. the control panel is powered by AC power or battery. Figure 3.5 – Optional GSM Module Mounting and SIM Card Insertion D-306048 WP8033 Installer's Guide...
  • Page 11: Output Interface Module Installation (Located In Place Of Detail "E" In Figure 3.1)

    (for further details see the output interface module Installation Instructions). The output interface module provides 5 solid state relay contact outputs and is designed to be used as a plug-in internal add-on module with the WP8033 control panel. Mount the output interface module as shown in Figure 3.6.
  • Page 12: Installing The Plink3 Dsc

    3.7 Installing the PLINK3 DSC The PLINK3 DSC is used to view and control the WP8033 system over the Internet. Perform the following instructions for the PLINK3 DSC installation. Note: PLINK3 DSC operation is not backed up by the control panel’s battery and it is shut down during AC failure.
  • Page 13: Optional Expander Module (Detail "I" In Figure 3.1)

    Caution! The receptacle with strain relief clip is for the front unit – do not connect it to the back unit! A. 2 clips B. Flat cable with one strain relief clip B1. This side for front unit B2. This side for back unit Figure 3.8a –Expander Module D-306048 WP8033 Installer's Guide...
  • Page 14 WARNING! When plugging terminals back into place, be sure to align them carefully with the pins on the PCB. Misaligned or reverse insertion of terminals may damage internal WP8033 circuits! IMPORTANT! The terminals for internal and external sirens are DC outputs intended for 12V sirens. Connecting a loudspeaker to any of these outputs will cause a short circuit and will damage the unit.
  • Page 15: Connecting Power To The Control Panel

    (D). 4. Connect the power supply output cable (G) to the power connector (H) in the front panel. Figure 3.9a – Power Cable Clamp Extraction and Power Connection for Internal Power Supply D-306048 WP8033 Installer's Guide...
  • Page 16: Battery Insertion

    Figure 3.9c – Battery Insertion 3.9.2 Connect AC Power to the Unit Connect power to the WP8033 to mains power outlet (see Figures 3.8a and 3.8b). Disregard any “trouble” indications pertaining to lack of battery or lack of telephone line connection.
  • Page 17: Closing The Wp8033 Control Panel

    3.10 Closing the WP8033 Control Panel Control panel final closure is shown below. To close the Control Panel: 1. Connect the flat cables, between front and back units, in their respective connectors (up to 3, according to options). 2. Make sure that the "Power" indicator on the control panel lights green.
  • Page 18: Visual Indications, First Keypad Enrollment And Using Prox Tag

    Press the "ENROLL" button (physically located inside the front unit of the WP8033 control panel – see Figure 3.1) for 2 seconds. If no keypad exists in the first location, the "ENROLL" LED on the WP8033 blinks slowly for 1 minute (go to step 3).
  • Page 19: Using The Prox Tag

    5.3 Fuse Replacement The WP8033 has two internal fuses that has automatic reset. Therefore, there is no need to replace the fuses. When over current condition occurs, the fuse cuts off the circuit current. Upon fault current being removed for several seconds, the fuse is automatically reset and allows current flow through the circuit again.
  • Page 20: Appendix A. Specifications

    380 mA 70 mA 125 mA 160 mA 35 mA 70 mA 95 mA max backup w/o 12 mA 25 mA load 22 hours no backup 0 mA 10 mA no backup no backup 0 mA D-306048 WP8033 Installer's Guide...
  • Page 21: A4. Communication

    Site Internal Siren Current (INT) 450* mA max @ 12.5 VDC when powered by AC/DC (10.5 VDC when in standby mode) Total WP8033 output current (of INT & EXT sirens, PGM output and detectors) cannot exceed 550 mA. Current sink to control panel GND 100 mA max.
  • Page 22: Appendix B. Compliance With Standards

    European CE Standards Standards The WP8033 complies with the RTTE requirements - Directive 1999/5/EC of the European Parliament and of the Council of 9 March 1999. According to the European standard EN50131-1 and EN 50131-3, the WP8033 security grading is 2 - "low to medium risk" and environmental classification is II –...
  • Page 23: Quick User Guide To Main Alarm Control Operations By The Keypad

    When pressing the Fire or Emergency icons, the keypad ( 2 sec.) starts beeping. After pressing the button for approx. 2 Fire alarm seconds, the keypad sends the command. ( 2 sec.) Panic alarm ( 2 sec.) D-306048 WP8033 Installer's Guide...
  • Page 24 Note: To quit at any stage and to revert to the "READY" display, click Device Locator: The WP8033 system has a powerful device locator that helps you to identify open or troubled devices indicated on the LCD display. While the LCD displays an open or faulty device, the LED on the respective device flashes indicating "it's me".

Table of Contents