5.7.3 PGM Output Configuration

Define which factors, including any combination of factors, will determine the PGM output.
Option
Configuration Instructions
PGM: BY ARM AWAY
Determine to activate the PGM output upon arming Away / Home / Disarm.
PGM: BY ARM HOME
Options: disable (default); turn ON; turn OFF; activate PULSE.
PGM: BY DISARM
Determine to activate the PGM output upon registration of an alarm in the memory. The
PGM: BY MEMORY
output will restore to normal upon memory clearing.
Options: disable (default); turn ON; turn OFF; activate PULSE.
Note: In Soak Test
activated.
Determine to activate the PGM output during the Exit and Entry delays.
PGM: BY DELAY
Determine to activate the PGM output upon pressing the AUX () button of keyfob
PGM: BY KEYFOB
transmitters configured to activate the PGM output. For further details, refer to the
configuration instructions of the AUX () button of the respective keyfobs' datasheets.
Determine to activate the PGM output upon activation of any one of up to 3 sensors (zones)
in the systems irrespective of whether the system is armed or disarmed.
To configure:
PGM: BY SENSOR
Press
 Zone A Z:_ _
program, for example "Zone A". If the zone was configured before, the display shows the
Zone B Z:_ _
current zone number "(Z:xx)" and if not, the zone number will be blank ("Z:_ _"). To
Zone C Z:_ _
configure the zone number, press
activate the PGM output and press
the other two options ("Zone B" and "Zone C") and repeat the above process.
When done press
Options: disabled (default); turn ON; turn OFF; activate PULSE; toggle
Note: If you select toggle, the PGM output will be turned on upon event occurrence in any
of these zones and will be turned off upon next event occurrence, alternately.
PGM:BY LINE FAIL
Determine to activate the PGM output following failure of the PSTN line
Options:
PGM:BY SIREN
Determine to activate the PGM output as an external wired siren.
Options:
PGM:PULSE TIME
Determine the PGM output pulse time. This value is the same for all events (by ARM AWAY,
by ARM HOME, by DISARM etc.) which were selected with "activate PULSE" option.
Options:
Note: PGM not to be enabled in UL Listed Product.
1
Soak Test is not applicable for UL installations
D-306233 CUSDOC PM-10/30 V18 DSC TRIPLE EN INST
1
mode and when BY MEMORY is enabled, the PGM will not be
Options: disable (default); turn ON; turn OFF; activate PULSE.
Options: disable (default); turn ON; turn OFF; activate PULSE; toggle
to enter the
"
by line fail NO (default); by line fail YES.
disable
(default) and
pu lse time 2s
sub menu and then select the Zone you wish to
PGM: BY SENSOR"
. Enter the Zone number (2 digits) you wish to
to confirm. To add another sensor, select any of
to return.
ON&OFF by siren
pulse time 30s; pulse time 2m; pulse time
(default);