A4. Communication; A5. Physical Properties; A6. Peripherals And Accessory Devices - DSC WP8010 Installer's Manual

Hide thumbs Also See for WP8010:
Table of Contents

Advertisement

3. WP8010 INSTALLATION

A4. Communication

WP8010
Communication
PSTN; GSM; GPRS; IP (for future use)
Built-in Modem
300 baud, Bell 103 protocol
Data Transfer to
Via RS232 serial port
Local Computer
Report
2 Monitoring Stations, 4 private telephones
Destinations
Reporting Format
SIA, Contact ID, Scancom, SIA IP, DSC
Options
PowerNet.
Note: For UL Listed product, the
communication formats used are SIA and
Contact ID.
Pulse Rate
10, 20, 33 and 40 pps - programmable
Message to Private
Tone
Phones
Ring Detection
The unit does not support ring detection
without DC voltage present on the telephone
lines.

A5. Physical Properties

WP8010
Operating Temp.
14°F to 120°F (-10°C to 49°C)
Range
Note: For UL Listed product, the ambient
temperature is 32°F to 120°F (0°C to 49°C)
Storage Temp.
-4°F to 140°F (-20°C to 60°C)
Range
Humidity
93% relative humidity, @ 30°C (86°F)
Size
196 x 180 x 55 mm (7-5/8 x 7 x 2 in.)
Weight
658g (23 Oz) (with battery)
Color
White

A6. Peripherals and Accessory Devices

WP8010
Modules
GSM/GPRS, IP (future use)
Additional
30 detectors, 8 keyfobs, 8 keypads, 4 sirens,
wireless devices
4 repeaters, 8 proximity tags
Wireless Devices
Magnetic Contact: PGx945, PGx975
and peripherals
PIR Detectors : PGx904; PGx904P, PGx994,
PGx984, PGx984P, PGx974, PGx974P,
PGx924, PGx944
PIR Camera Detectors: PGx934; PGx934P
Smoke Detector: PGx926/ PGx916
(
GSM Module: WPGSM
Keyfob: PGx939, PGx929Keypad: WP-LED
(with tag), WP-Touch Indoor Siren:
PGx901/PG9901
Outdoor Sirens: PGx911, PG9911Repeater:
PGx920
Gas: PGx913 (CO detektor)
Glass-break: PGx912
Temperature: PGx905
Shock: PGx935
Note: UL requires that when using remote
smoke/CO detectors and repeaters, each
detector must be within range (STRONG) of 2
1
For EN/European compliance setting: Dual reporting PowerLink3 and PSTN (for both WP8010and WP8030) or PowerLink3 and GSM
only for WP8030.
84
1
optional)
WP8030
PSTN; GSM; GPRS; IP (for future use)
300 baud, Bell 103 protocol
Via RS232 serial port
2 Monitoring Stations, 4 private telephones
SIA, Contact ID, Scancom, SIA IP, DSC
PowerNet.
Note: For UL Listed product, the
communication formats used are SIA and
Contact ID.
10, 20, 33 and 40 pps - programmable
Tone or voice
The unit does not support ring detection
without DC voltage present on the telephone
lines
WP8030
14°F to 120°F (-10°C to 49°C)
Note: For UL Listed product, the ambient
temperature is 32°F to 120°F (0°C to 49°C)
-4°F to 140°F (-20°C to 60°C)
93% relative humidity, @ 30°C (86°F)
266 x 201 x 63 mm (10-7/16 x 7-7/8 x 2-1/2 in.)
1.44Kg (3.2 pounds) (with battery)
White
WP8030
GSM/GPRS, IP (future use)
64 detectors, 32 keyfobs, 32 keypads, 8
sirens, 4 repeaters , 32 proximity tags
Magnetic Contact: PGx945, PGx975
PIR Detectors : PGx904; PGx904P, PGx994,
PGx984, PGx984P, PGx974, PGx974P,
PGx924, PGx944
PIR Camera Detectors: PGx934; PGx934P
Smoke Detector: PGx926/ PGx916
(optional)GSM Module: WPGSM
Keyfob: PGx939, PGx929Keypad: WP-LED
(with tag), WP-Touch Indoor Siren:
PGx901/PG9901
Outdoor Sirens: PGx911, PG9911
Repeater: PGx920
Gas: PGx913 (CO detector)
Glass-break: PGx912
Temperature: PGx905
Shock: PGx935
Note: UL requires that when using remote
smoke/CO detectors and repeaters, each
detector must be within range (STRONG) of 2
repeaters at all times (for path redundancy –
D-306233 CUSDOC PM-10/30 V18 DSC TRIPLE EN INST

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wp8030

Table of Contents