3. WP8010 INSTALLATION

5.9.4 Testing the SIM Number

The WP8010/WP8030 enables to test the SIM number to ensure the SIM number was entered correctly in the control
panel (see section 5.6.3) and to coordinate with the operator.
07:DIAGNOSTICS
Enter the "SIM NUMBER TEST" menu, select the IP server (out of two) used for the verification of the SIM and press
. The panel sends a test SMS to the server.
If the server receives the SMS, the control panel will display "SIM# verified" and the test ends successfully. If the SMS
was not received, for example, if there is no connection between the control panel and server, the control panel will
display "SIM not verified".

5.9.5 Testing the Broadband/PowerLink Module

The Broadband diagnostic procedure enables to test the communication of the Broadband Module (see section 5.6.8)
with the PowerManage server and reports the diagnostic result. In case of communication failure, detailed information
of the failure is reported.
07:DIAGNOSTICS
Notes:
1. When the
button is pressed, the test result may take up to 4 min. before it is displayed.
2. If the Broadband Module is not registered to the WP8010/WP8030, the menu "BROADBAND MODULE" will not be
displayed.
The following table presents the list of messages that may be reported:
Message
Unit is ok
Broadband Module is functioning correctly.
Test aborted
The diagnostic test is aborted, as follows:
 AC failure – Broadband Module is set to OFF mode.
 Broadband Module has not completed the power-up procedure. In this case, the installer should
wait a maximum of 30 seconds before re-testing.
Comm. loss
The RS-232 serial interface between the Broadband Module and the WP8010/WP8030 failed.
Rcvr Ip missing
Receivers IP 1 and 2 settings are missing in the WP8010/WP8030.
Cable unplugged
The Ethernet cable is not connected to the Broadband Module.
Check lan config
This message appears in any of the following cases:
 Incorrect Broadband Module IP has been entered.
 Incorrect subnet mask has been entered.
 Incorrect default gateway has been entered.
 DHCP server failure.
Rcvr#1 UnReach.
Receiver 1 or 2 is inaccessible, as follows:
 Wrong receiver IP has been entered.
Rcvr#2 UnReach.
 Receiver failure.
 WAN Network failure.
Rcvr#1 UnReg.
The WP8010/WP8030 unit is not registered to IP receiver 1 or 2.
Rcvr#2 UnReg.
Timeout err.
Broadband Module does not respond to test result within 70 sec.
Invalid result
Broadband Module responds with a result code that is not recognized by the WP8010/WP8030.

5.10 User Settings

This USER SETTINGS menu provides you with a gateway to the user settings through the regular user menus.
Refer to the WP8010/WP8030 User's Guide for detailed procedures.
1
SIM number test is not applicable for UL installations
2
Broadband is not applicable for UL installations
3