Step 4.
Close the panel and secure with 2 screws:
WP8010

Control Panel Configuration

The PowerLink3 IP Communicator is integrated with the WP8010/WP8030 control panel. This facilitates in the setup of
the required menus that are familiar to the installer.
For detailed programming instructions of the menus, the installer should refer to section 5.6 "Communication".
Setting the Communication Channel
Follow the instructions below to enable DHCP or to set the PowerLink3 IP Communicator IP address.
1. From the WP8010/WP8030 control panel, enter "INSTALLER MODE" menu using the Installer Code.
2. Enter the "04:COMMUNICATION" menu.
3. Enter the "7:BROADBAND" menu.
4. Select "Manual IP or "DHCP Client" and set either one.
Note If "7:BROADBAND" does not appear or if it is not possible to enter the menu, check to make sure that the
PowerLink3 IP Communicator has been correctly installed.
Programming for Configuring Events Reporting to Central Stations
Follow the instructions below to select the type of events to be reported and to determine the method used for reporting
events.
1. From the WP8010/WP8030 control panel, enter "INSTALLER MODE" menu using the Installer Code.
2. Enter the "04:COMMUNICATION" menu.
3. Enter the "3:C.S. REPORTING" sub-menu.
4. Program the following menus:
"01:REPORT EVENTS" – Select the type of events that the control panel will report to the Central Station.
"02:1st RPRT CHAN/03:2nd RPRT CHAN/04:3rd RPRT CHAN" – Define the 1
to report events. Select the "broadband" option for PowerLink3 IP Communicator.
"21:IP RCVR 1/22:IP RCVR 2" – Enter the Central Station IP address the PowerLink3 IP Communicator will
report to (not mandatory field).
D-306233 CUSDOC PM-10/30 V18 DSC TRIPLE EN INST
3. WP8010 INSTALLATION
WP8030
st
nd
rd
/2
/3
priority of method used
97