3. WP8010 INSTALLATION

5.14 Operation Mode

Notes:
1. The Operation Mode feature is applicable only in specific WP8010/WP8030 variants.
2. For UL installations, Operation Mode must be "normal".
5.14.1 General Guidance – "Operation Mode" Menu
This mode allows you to select an operation mode for the control panel according to specific compliance standards.
Each operation mode has its own configuration.

5.14.2 Select setting

To select the desired operation mode, proceed as follows:
Step 1
Select "13:OPERATION MOD" menu
13:OPERATION MOD
Note: If "Normal / EN-50131 / INCERT" is selected, the control panel will operate according to OTHERS setup
configuration (see section 5.14.6).

5.14.3 BS8243 Setup

13:OPERATION MOD
Enter the "02:BS8243 SETUP " menu to configure its settings.
Option
Configuration Instructions
Define when it is possible to disarm the system:
01:DISARM OPTION
entry/BS devs (default) – By keypad after the entry delay has expired and if an alarm occurred
in the system. By keyfob or WP-TOUCH (868-3:037) at all times.
entry/all devs - During entry delay, when the system is armed AWAY, by all devices. When
not in entry delay by keyfob or WP-TOUCH (868-3:037)only.
entry/DD devs - During entry delay, when the system is armed AWAY, by using the keyfob or
WP-TOUCH (868-3:037)Keypads cannot disarm at all.
anytime/all dev – At any time and by all devices.
02:ENTRY ALARM
Define whether the system will report a confirmed alarm during an entry delay (see CONFIRM
ALARM below).
BS8243 (default) – An alarm initiated by another detector during the entry delay is regarded as
a confirmed alarm. An additional 30 seconds delay is added to the entry delay for reporting the
event (does not affect the Abort Time, see section 5.5.4).
BS8243 no cnfrm - The panel will not send any confirmed alarm once a delay zone has been
activated, until the control panel is disarmed.
DD243 - An alarm initiated by another detector during the entry delay is not regarded as a
confirmed alarm.
normal mode - The control panel will report a confirmed alarm for the second alarm that is
triggered from a different zone within the confirmation time. There are no alarm restrictions
during entry delay or for the delay zone.
03:END EXIT MODE
Define how the exit delay is terminated or restarted according to the following options:
door/fob only (default) - When the door is closed, or by pressing the AUX button on the
keyfob
restart>reentry - Exit delay restarts when the door is reopened during exit delay. The restart
occurs once only. Restarting the exit delay is helpful if the user re-enters immediately after
going out to retrieve an item that was left behind.
door/fob/timer - When the door is closed, by pressing the AUX button on the keyfob
the exit delay has expired, whichever first.
fob/timer - By pressing the AUX button on the keyfob
whichever first.
1
Applies only when the keyfob is defined as "skip exit delay" (for further details, see the keyfob's User's Guide)
68
Step 2
Enter "01:SELECT MODE"
01 SELECT MODE
  
02:BS8243 SETUP
1
, whichever first.
Step 3
Select "Normal", "EN-50131",
"DD243", "BS8243", "INCERT" or
"CP01"
Normal
1
, or when the exit delay has expired,
D-306233 CUSDOC PM-10/30 V18 DSC TRIPLE EN INST
Step 4
 to Step 2
1
, or when